1. General Information and Warnings 

1.1. FCC Declarations of Compliance

 - FCC Déclaration de conformité 

United States 

This  equipment  has  been  tested  and  found  to  comply  with  the  limits  for  a  Class  A  digital  device, 
pursuant  to  Part  15  of  the  FCC  Rules.  These  limits  are  designed  to  provide  reasonable  protection 
against  harmful  interference  when  the  equipment  is  operated  in  a  commercial  environment.  This 
equipment generates, uses, and can radiate radio frequency energy and, if not installed and used in 
accordance  with  the  instruction  manual,  may  cause  harmful  interference  to  radio  communications. 
Operation of this equipment in a residential area is likely to cause harmful interference in which case 
the user will be required to correct the interference at his own expense. 

 
Canada 

This  digital  apparatus  does  not  exceed  the  Class  A  limits  for  radio  noise  emissions  from  digital 
apparatus  set  out  in  the  Radio  Interference  Regulations  of  the  Canadian  Department  of 
Communications. 

Le présent appareil numérique n’émet pas de bruits radioélectriques dépassant les limites applicables 
aux  appareils  numériques  de  la  Classe  A  prescrites  dans  le  Règlement  sur  le  brouillage 
radioélectrique  edicté  par  le  ministère  des  Communications  du  Canada.Interference  Regulations  of 
the Canadian Department of Communications. 

 
 

 

 

Summary of Contents for C3236

Page 1: ...AWT35 501815 Issue AB C3236_u_en_501815 docx Page 1 User Manual Model C3236 Checkweigher...

Page 2: ...ntretien de routine 6 Cleaning the Machine Nettoyage de la machine 6 Sharp Objects Objets tranchants 6 2 Introduction page 7 Unpacking 7 General Installation Guidelines 7 Levelling the Scale 7 Battery...

Page 3: ...iptions UF 12 Supervisor Menu 13 Supervisor Menu Levels 13 Supervisor Functions Descriptions LF 14 Quick Calibration Menu 15 Quick Calibration Menu Levels 15 Quick Calibration Functions Descriptions E...

Page 4: ...AWT35 501815 Issue AB C3236_u_en_501815 docx Page 4 Manual revision history Current Issue Date Created Details of Changes Draft Jan 2019 New...

Page 5: ...tion manual may cause harmful interference to radio communications Operation of this equipment in a residential area is likely to cause harmful interference in which case the user will be required to...

Page 6: ...operation and calibration Application and usage will determine the frequency of calibration required for safe operation PRUDENCE Le fonctionnement et l talonnage de cet quipement doivent tre v rifi s...

Page 7: ...ht or near air vents Place the scale on a level flat surface Do not place the scale near vibrating machinery Avoid unstable power sources Do not use near large users of electricity e g welding equipme...

Page 8: ...le please insure the power adaptor is fully removed from the scale prior to cleaning Figure 1 C3236 underside view 2 5 Front Panel Figure 2 shows the front panel of the unit It includes the display wi...

Page 9: ...n the scale The scale will self adjust to 0 Press this key to Zero the display Press this key to Tare the weight on the scale up to 100 of capacity In Menu mode It accepts the displayed item value in...

Page 10: ...the scale platform 4 Press the ON ZERO TARE key If the container weight is outside the Zero window area the display will show 0 000 weight and the NET annunciator is illuminated 5 Place the item to b...

Page 11: ...RE key Press the FN key to increase the value of the flashing digit viii Press ON ZERO TARE key to complete and leave the procedure ix Press UNITS ESC key to exit the User Menu To disable the checkwei...

Page 12: ...and increase a numeric value by pressing FN key Use ON ZERO TARE key to confirm and or move to the next option or numeric value position Press UNITS ESC key to exit the option or the menu 4 1 2 User...

Page 13: ...Values between 01 and 99 seconds are valid UF 5 ADC Update Rate use this to select the sampling frequency 15 1 30 2 or 7 5Hz 3 See Supervisor Menu UF 6 Automatic Zero Tracking use this to define a 0 5...

Page 14: ...a possible mechanical problem or possible load cell failure which linearity calibration may not be able to correct LF 4 ADC Update Rate use this to select the sampling frequency 15 1 30 2 or 7 5Hz 3 F...

Page 15: ...uick Calibration Menu Levels ECF Navigate the menus and increase a numeric value by pressing FN key Use ON ZERO TARE key to confirm and or move to the next option or numeric value position Press UNIT...

Page 16: ...to set the units range mode calibration units decimal position of the separator and division size Navigate the menus and increase a numeric value by pressing FN key Use ON ZERO TARE key to confirm and...

Page 17: ...few divisions If large inaccuracies are recorded this indicates a possible mechanical problem or possible loadcell failure which linearity calibration may not be able to correct LF 2 CALIBRATION SETT...

Page 18: ...number Description AWT25 502472 Power supply universal with USA UK EU plug adaptors 100 to 240VAC 50 60 Hz output 12V 1000mA with special water proof 2 pin connector Replacement battery DJW6 4 0 6V4...

Page 19: ...AWT35 501815 Issue AB C3236_u_en_501815 docx Page 19...

Reviews: