![Brecknell C3236 User Manual Download Page 11](http://html1.mh-extra.com/html/brecknell/c3236/c3236_user-manual_2806435011.webp)
AWT35-501815 Issue AB C3236_u_en_501815.docx
Page 11
3.3.1. Setting the Checkweighing Limits
i.
When the scale is ON, press
FN
(▲) key;
UF-1 will be displayed.
ii.
Press
FN
(▲) key;
UF-2 will be displayed.
iii.
Press
ON/ZERO/TARE
(
↵
) key;
iv.
To enter or edit the
LO
limit value, scroll through the
displayed digits by using the
ON/ZERO/TARE
(
↵
)
key. Press the
FN
(▲) key to increase the value of
the flashing digit.
v.
Press
ON/ZERO/TARE
(
↵
)
key
to confirm;
vi.
Repeat points
iv.
and
v.
for the
HI
limit;
vii.
Choose the
beeper mode [000; 001; 002]
navigating the decimal position by pressing
ON/ZERO/TARE
(
↵
)
key. Press the
FN
(▲) key to
increase the value of the flashing digit.
viii.
Press
ON/ZERO/TARE
(
↵
)
key to complete and
leave the procedure;
ix.
Press
UNITS
(
ESC
)
key
to exit the User Menu.
To disable the checkweighing feature, set the Hi and Lo limits to 0 in the User Menu [UF-
2].
The LO and HI annunciators will be turned off.
3.3.2. Checkweighing Beeper Modes
There are three modes.
o 000
The beeper is disabled.
o 001
The beeper sounds only when the load is within the acceptable limits.
o 002
The beeper sounds only when the load is outside the acceptable limits.
Please, ignore any other mode not listed above.
3.4. Changing Units of Measure
1. With the scale turned on press the
UNITS
key to select the required unit of measure you want the
scale to work in from kg
– grams –lb.