8 Technical Specifications

Breas HA 01 Humidifier User Manual

Doc. 004221 En T-2

5

Technical Specifications

5.1 Data        

P

OWER

 

SUPPLIES

S

PECIFICATION

Power supply

12-30 V DC, max 40 W.

E

NVIRONMENTAL

 

C

ONDITIONS

S

PECIFICATION

Operating temperature
range

5 to 40°C (41 to 104°F)

Storage and transport tem-
perature

-20 to +60°C (-4 to +140°F)

Ambient pressure range

700 to 1060 mbar

Humidity

10% to 95%, non-condensing

D

IMENSIONS

S

PECIFICATIONS

× 

×

 D

148 

× 

155 

×

 98 mm

Weight

260 g

Air outlet

22 mm conical standard connector

P

ERFORMANCE

S

PECIFICATIONS

Gas leakage at max. operat-
ing pressure

< 5 ml/min

Summary of Contents for HA 01

Page 1: ...ded to humidify the patient air User Manual for Breas HA 01 Humidifier Read this manual thoroughly so that you completely understand how the humidifier is operated and maintained before taking it into...

Page 2: ...highlight specific information The meaning of each icon is explained in the table below For complete instructions how to operate the humdifier refer to the Breas breathing therapy equipment manual IC...

Page 3: ...ated humidifier may require the installation of a water trap in the circuit The water trap prevents any condensated water in the patient circuit from run ning into the patient airways and causing pers...

Page 4: ...below 10 RH room humidity and above 95 RH atmosphere pressure below 700 mbar and above 1060 mbar The humidifier any accessories and all replaced parts must be disposed of in accordance with the local...

Page 5: ...quipment Designation and Safety Label NO COMPONENT FUNCTION 1 Humidifier lid Sealing the humidifier 2 Internal pipe To prevent water spillage into the Breas breathing therapy equipment 3 Swivel Patien...

Page 6: ...it may be returned to Breas Medical AB for scrap ping and should not be discarded with the household waste Never add or pour out water from the humidifier when attached to the Breas breathing therapy...

Page 7: ...difier can be disinfected with Virkon or Lysetol 4 1 Disposal The humidifier any accessories and all replaced parts must be disposed of and recycled in accordance with the local environmental regulati...

Page 8: ...NTAL CONDITIONS SPECIFICATION Operating temperature range 5 to 40 C 41 to 104 F Storage and transport tem perature 20 to 60 C 4 to 140 F Ambient pressure range 700 to 1060 mbar Humidity 10 to 95 non c...

Page 9: ...output of the humidifier at the patient end of the tube The warm up time for the delivered gas temperature to reach the set tempera ture from a starting temperature of 23 2 C is less than 60 minutes w...

Page 10: ...1 4 2000 Medical electrical equipment Part 1 4 Gen eral requirements for safety Collateral Stand ard Programmable electrical medical systems IEC 60601 1 6 2004 Medical electrical equipment Part 1 6 Ge...

Page 11: ...11 Notes Breas HA 01 Humidifier User Manual Doc 004221 En T 2 6 Notes...

Reviews: