Page
4
sur
12
POSITIONING
This device is only made to be used indoor and must be installed in vertical
position. It has to be fixed to the wall at more the less than 1.30m, preferably
in an accessible and clean area.
The units must only be used in areas which are free of dust and possible explosive
vapour mixture. Should you have any queries contact your local reseller for advice
before installation.
INSTALLATION
1. Fix the 3/4 screws and dowels according to plan bellow
2. Hang it by sliding screw’s heads into corresponding holes
3. Open the door and tighten the screws to lock fixing
4. Connect the appliance to a power outlet corresponding
to the power requirements
5. A sterilizing cycle will start automatically.
SERVICING
Changing of the UV-C bulb by any
non-qualified user is strictly forbidden
. Before any form
of servicing, even like bulb replacement, the unit must be disconnected from the mains supply.
To maintain the sterilizing efficiency, the UV-C bulbs have to be replaced once a year.
CLEANING
The internal cleaning of this device can only be made by using a slightly damp towel. Any
internal or external water projection have to be avoided.
GUARANTEE
Your unit is guaranteed for 2 years (excluding bulbs replacement). If a fault occurs, contact your
supplier, who will replace your unit checking that the product has been operated under normal
conditions.
25.06.2019
Indice C
MODELS
ARM25 A/P ARM50 A/P ARM100 A/P
A
230mm
380mm
A = 800mm = B
MODELS
ARM25P ARM25A
ARM50P
ARM50A ARM100P ARM100A
Maximum knives
12
7
20
10
40
20
Knives fixing
Rack
Magnet
Rack
Magnet
Rack
Magnet
UV bulb
1x15W
1x15W
1x15W
1x15W
2x15W
2x15W
Height (mm)
593
593
593
593
593
593
Depth (mm)
145
145
145
145
145
145
Width (mm)
345
345
495
495
939
939
Weight (kg)
5,5 kg
5,5 kg
6,5 kg
6,5 kg
11,5 kg
11,5 kg
B
A
3
50
BRC SAS – 21 rue des coteaux de Grand Lieux – 44830 BOUAYE