background image

USER AND MAINTENANCE MANUAL

 

Original instructions

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

SOLO  GYPS 

 

DRYWALL PANEL HOIST

 

September 2020 rev0

 

EC Directives 

 

English

 

Summary of Contents for SOLO GYPS

Page 1: ...USER AND MAINTENANCE MANUAL Original instructions SOLO GYPS DRYWALL PANEL HOIST September 2020 rev0 EC Directives English ...

Page 2: ... its readability To make the consultation easier the manual has been divided into parts so that each step is well articulated For practicalness of use each subject has been divided into numbered steps which when the action requires it are written on the drawings themselves Parts that need more attention are highlighted with symbols and well detailed illustrations on the side of the page In this wa...

Page 3: ...PIERINO POSITION MANAGING DIRECTOR DATE _________________________ NOTIFIED BODY RESIDUAL RISKS Even if Braviisol Divisione Meccanica srl has done everything possible to manufacture the SOLO GYPS drywall panel hoist with the greatest knowledge in its possession on security and consulting all the di rectives laws and regulations at its disposal still exist even if reduced some residual risks during ...

Page 4: ...oductory Informations 1 5 Part 2 Safety Prescriptions 2 11 Part 3 Machine Specifications 3 13 Part 4 Installation and Assembly 4 14 Part 5 Control panel 5 20 Part 6 Operations 6 21 Part 7 Cleaning 7 23 Part 8 Ordinary Maintenance 8 24 Part 9 Technical Informations 9 27 09 2020 Rev 00 ...

Page 5: ... has been supplied the present manual And that the operator takes the responsibility of following it step by step Braviisol Divisione Meccanica srl informs that any modification or tampering of the SOLO GYPS drywall panel hoist and or operations carried out not in compliance with what is written in this manual especial ly the non observance of safety requirements will invalidate the warranty and t...

Page 6: ...t the bottom of each page Each SOLO GYPS drywall panel hoist has its own number with the consequent CE marking 1 2 2 To contact Braviisol Divisione Meccanica srl or its centres of assistance concerning the SOLO GYPS drywall panel hoist please always refer the model and serial number legibly affixed to the identification plate 09 2020 Rev 00 ...

Page 7: ... 4 The safety devices at the time of delivery are in perfect efficiency 5 The present manual has been delivered together with the equipment 6 The operator accepts the responsibility point by point of the following In case of damages or missing parts please immediately contact the Manufacturer his local represent atives the dispatcher or the insurance company providing detailed information and or p...

Page 8: ...urer to be defective in material and or workmanship Furthermore warranty claims can be accepted ONLY when all information specifically required by the Manufacturer such as Serial Number are provided The manufacturer reserves the right to replace repair exchange or to provide a new used or rebuilt component assembly sub assembly or weldment based on its unquestionable judgment THIS WARRANTY POLICY ...

Page 9: ... will be sent back to the Manufacturer If required please take photographs of the defective part and of the area where the machine has been operated This is both to prevent unpleasant controversies and to improve the quality warranty and safety of our machines THIS WARRANTY STATEMENT IS EXCLUSIVE AND IN LIEU OF ALL OTHER WARRANTIES EXPRESSED OR IMPLIED ALL SUCH OTHER WARRANTIES INCLUDING IMPLIED W...

Page 10: ...all lifts and make the job safer Com posed by a lightweight electric powered track and detachable adjustable frame to hold and lift sheets The setup of this device requires no tools and its very fast Once the job is completed it is quickly removable for easy storage The cradle can be adjusted to hold panels lomg up to 365cm x 120cm 12 ft x 4ft and lowers off the floor for easy panel loading It can...

Page 11: ...dition that may affect pro per operation Any part that is damaged should be properly repaired or replaced by a qualified technician Do not use the device if any switch does not operate pro perly Check the load cradle chain in order to verify if damages are present h Replacement parts and accessories When servicing use only identical re placement parts Use of any other parts will void the warranty ...

Page 12: ...xtendable arms and crossarms are not in place p Manouvers Do not manouver the platform in order to have rough move ments q Electrocution shock Keep the device away from live electrical wires Please refer to the Platform user and maintenance manual regarding the di stances Failure to do this could result in electrocution 09 2020 Rev 00 ...

Page 13: ...O GYPS DRYWALL PANEL HOIST SPECIFICATIONS DRYWALL PANEL QUANTITY CAPACITY 1 LOAD RATING 40 Kg 89 Lbs NET WEIGHT 45Kg 99 2 Lbs DRYWALL PANEL SIZE CAPACITY 365 cm x 120 cm 12 ft x 4ft Load Cradle Rising button Load Cradle Lowering button 09 2020 Rev 00 ...

Page 14: ...hoist installation it is necessary to bring the Platform to the Zero Power Condition that is Platform completely lowered see PART 5 of the Platform user manual The emergency buttons pressed see Platform user manual The Q2 Key switch must be removed from the Ground module and handed over to the Production Manager see Platform user manual 09 2020 Rev 00 ...

Page 15: ...TION ON LEONARDO HD 1 Install the Solo Gyps drywall panel hoist main frame matching the anchorage point to the Leonardo HD lateral side cage as showed in fig1b 2 Insert the safety pins for the anchorage points as showed in fig2b Anchorage points fig1b 09 2020 Rev 00 ...

Page 16: ...2011 Rev 00 3 Install the load cradle to the main frame as showed in fig 3a 4 Install the crossarms to the extendable arms as showed in fig4a Secure them using the safety pin one position available fig5a Safety pins fig2b fig3a 09 2020 Rev 00 ...

Page 17: ...t 4 Installation and Assembly 07 2011 Rev 00 fig4a fig5a 5 Install the extendable arms to the load cradle as showed in fig 6a Secure them using the safety pins two positions available fig7a fig8a 09 2020 Rev 00 ...

Page 18: ...07 2011 Rev 00 4 18 Part 4 Installation and Assembly fig6a fig7a fig8a 09 2020 Rev 00 ...

Page 19: ... drywall panel hoist plug to the Platform s socket as showed in fig 3b Secure the electric cable as showed in photo 7 For Leonardo HD connect the Solo Gyps drywall panel hoist plug to the Platform s socket as showed in fig 4b Secure the electric cable to the eye bolt fig4b fig3b 09 2020 Rev 00 ...

Page 20: ... Keep pushed this button the load cradle will lift from the upper position to the lower position of the de vice 5 2 FUNCTION TEST 5 2 1 Press and keep pressed the load cradle rising button P2 to allow the raising of the load cradle If you want to stop the raising release the button 5 2 2 Press and keep pressed the load cradle lowering button P3 to allow the lowering of the load cradle If you want ...

Page 21: ...ing the translation and or lifting lowering operation the operator must paying attention in order that the working area on the ground and over the basket is always free from obstacles or dangers 6 3 Drywall Panel Installation Procedure Drive the Platform with the Solo Gyps drywall hoist installed on board at the desired position following the instruction of the 6 1 of this manual At this point the...

Page 22: ...ht fig2 Fix the drywall panel at the wall Lower the platform at the minimum height Repeat the procedure Due to the fact the Solo Gyps drywall panel hoist is electrically connected to the Platform batte ries check during operations the top control battery gauge in order to verify the battery charge level 09 2020 Rev 00 ...

Page 23: ...ll understood the safety prescriptions shown in this manual Part 2 7 1 c Before each cleaning operation bring the Platform to the Zero Power Condition and unplug the Solo Gyps Drywall panel hoist electric cable from the platform 7 1 d With a cloth slightly dampened with water clean the switchboards the safety pins the load cradle the extendable arms and the main frame 7 1 e The cleaning procedure ...

Page 24: ...less where specified NEVER BY MORE PEOPLE 8 1 d Warning Generic Risks The maintenance operations must be carried out by qualified staff who has read and well understood the safety prescriptions shown in this manual see Part 2 who has the individual safety devices and use them when necessary must have on disposal clothes suitable equipments and must wear and use them de pending on the necessities a...

Page 25: ...07 2011 Rev 00 8 25 Part 8 Ordinary Maintenance 09 2020 Rev 00 ...

Page 26: ...ATE 15 304 9004 1 CABLE REELS 16 217 10019 1 LOWER COVER 17 217 10013 1 UPPER COVER 18 217 60019 1 STRIP BRUSH 19 217 60020 1 STRIP BRUSH 20 107 203501 8 SPRING 21 217 10014 1 ELECTRIC MOTOR COVER 22 217 10012 1 CONTROL PANEL COVER 23 316 0001 1 STOP EMERGENZI BUTTON 24 316 0002 2 RISING LOWER BUTTON 25 316 0012 4 NO SWITCH 26 316 0013 2 NC SWITCH 27 315 0002 2 RELAY SOCKET 28 315 0001 2 RELAY 29 ...

Page 27: ...07 2011 Rev 00 9 27 Part 9 Technical Informations 9 1 ELECTRIC DIAGRAM 09 2020 Rev 00 ...

Page 28: ...BRAVIISOL Divisione Meccanica S r l S S 16 Adriatica km 314 600 60022 Castelfidardo AN Tel 071 7819090 Fax 071 7819355 E mail info bravi platforms com Website www bravi platforms com ...

Reviews: