background image

Page 13

Lift Wiring Diagram

Platform Lights (Option) 

Circuit Sentry 

(

Circuit Breaker) 

Bat.

Aux.

Lift

Power Cable 

205-0712-37

Pump Module 

Power Feed 

26082A-4

Connects to

Vehicle Battery  

(+) Positive Post 

Lead Wire 

13362A 

GN(20)

)

0

2(

K

B

RD(20)

or

Note polarity of diode.  It
must be oriented as shown. 
Detail at left shows two different  
styles of diode identification. 

)

4

1(

N

G

RL3

BK(4)

GN(20)

BK

RD

GN(20)

WH(20)

)

0

2(

N

G

)

4

1(

D

R

d

n

u

or

G

p

m

u

Ground

BU(16)

BK(24) COPPER 

BK(24) COPPER 

BK / WH(24) SILVER 

BK(24 GA

 COPPER) 

BK

GN

WH

RD

BK / WH(24 GA

 SIL

VER) 

BK / WH(24) SILVER 

BK(24 GA

 COPPER) 

BK / WH(24 GA

 SIL

VER) 

FS2

FS10

FS3

FS5

FS8

FS9

FS12

FS13

FS14

FS7

FS4

FS1

FS20

FS21

FS11 

WH(20)

GN(20)

PK(20)

Up/Fold

Solenoid

Motor Power Feed Wire 

Beeper

Threshold

Warning 

Light

Outboard

Barrier

Raised Sensor 

Ground

Detect

Sensor

Lift

Control
Module

Interlock LED 

Back
Plate

(Side view of

solenoids removed 

 from pump.) 

Hydraulic

Pump

J7

PURPLE(20)

YELLOW(20)

BLUE(20)

GREEN(20) (To J27)

ORANGE(20) (To J27)

RED(20) (To J27)

NOT USED 

WHITE(20) (To P25)

BLACK(20) (To P25)

6

5

4

3

2

1

COLOR

NO.

18-COND WIRE CODE 

7

8

9

11 10

13 12

14

15

16

17

18

2

1

4

3

5

6

7

8

9

J9

J8

J4

J3

B

T

A  U X

GN(20)

RD(20)

GN(20)

J28

P28

P15

J15

J15

P15

P32

J32

J25

P25

P26

J26

P27

P8

P5

P3

P9

P6

P7

P16

P20

J20

P20

J20

J30

J16

P16

J16

RL5

RL6

7

R

2

R

1

R

4

R

J27

31030A45

31010FA - Front Pump 

31010RA - Rear Pump  

30433A60

985-A1534NA 

985-2535NA

 

+
-

Down

Threshold Sensors 

IB Raised 

Sensor

Counter

BLACK (To C1) 

WHITE (To C1) 

NOT USED 

GREEN (To P28) 

ORANGE (To P28) 

RED (To P28) 

NOT USED 

NOT USED 

NOT USED 

15

14

13

12

11 

10

COLOR

NO.

16

17

18

Down

Dual Relief 

Power

Stud

31221A 

31221A 

RD(4)

RD(14)

RD(2)

RD(2)

BK(6)

Lift Power 

Switch

BK

RD(20)

GY/RD(18)

GY/RD(18)

985-0531NA 

985-2541NA 

N

2

3

5

2-

5

8

9

26161A-84

N

3

3

5

2-

5

8

9

RD(20)

RD(20)

GN(20)

WH(20)

BK(20)

BK(20)

BK(20)

RD(20)

BK(20)

4

5

3

3

0

1

3

31033A99

)

8

1(

K

B

)

8

1(

K

B

)

8

1(

K

B

)

8

1(

K

B

RD(20)

BK(20)

RD

GN

J6

J13

J5

+ -

-

E

+

P13

BU(16)

BU(16)

WH(20)

BK(20)

Bridge

Microswitch

COM

NO

NC

30433A60

GREEN(26)

RED(26)

YELLOW(26)

3

2

1

COLOR

NO.

3-COND WIRE CODE 

GREEN(20)

RED(20)

ORANGE(20)

3

2

1

COLOR

NO.

3-COND WIRE CODE 

1
2

1
2

3 2 1

1 2 3

GREEN(26)

RED(26)

YELLOW(26)

3

2

1

COLOR

NO.

3-COND WIRE CODE 

GREEN

RED

ORANGE

3

2

1

COLOR

NO.

3-COND WIRE CODE 

3

2

1

1

2

3

BLACK (To FS20) 

RED (To FS21) 

NOT USED 

NOT USED 

RED (To J30) 

GREEN (To J30) 

6

5

4

3

2

1

COLOR

NO.

12-COND WIRE CODE 

BLACK (To J30) 

GREEN (To FS12) 

BLACK (To FS14) 

RED (To FS13) 

NOT USED 

NOT USED 

12

11 

10

9

8

7

1

2

3

4

5

6

7

8

9

10

11 

12

PINK(20)

BLACK(20)

BLUE(16)

NOT USED 

RED(20)

WHITE(20) & WHITE(20) 

6

5

4

3

2

1

COLOR

NO.

6-COND WIRE CODE 

3

2

1

5

4

6

NOT USED 

NOT USED 

GREEN

WHITE

BLACK

RED

6

5

4

3

2

1

COLOR

NO.

6-COND WIRE CODE 

3

2

1

5

4

6

3

2

1

6

5

7

4

8

GRAY / RED(18) 

BLACK(20) & WHITE(20) 

RED(20) & GREEN(20) 

NOT USED 

4

3

2

1

COLOR

NO.

4-COND WIRE CODE 

2

1

4

3

Dual

Relief

1

2

2

1

1

2

1

2

2

1

1

2

2 1

1

2

2 1

Note:  All wires 22 GA.  
unless otherwise noted. 

GREEN

NOT USED 

NOT USED 

NOT USED 

D

C

B

COLOR

NO.

6-COND WIRE CODE 

RED

BLACK

F

E

C1

2

1

2

2

1

2

1

1

2

1

2

1

Rotary

Position

Sensor

Floor Level 

Memory Set 

Push Button 

A  B C D E F

ORANGE JUMPER #1 (CAVITY #2 TO #4) 

ORANGE JUMPER #2 (CAVITY #3 TO #8) 

IB Occupancy 

Microswitch

C-H

COM

NO

NC

WH

BK

4

N.O.

N.C.

.

M

O

C

PURPLE(20)

BLUE(20)

YELLOW(20)

3

2

1

COLOR

NO.

3-COND WIRE CODE 

1 2 3

3 2 1

3

2

1

COLOR

NO.

3-COND WIRE CODE 

GREEN(26)

RED(26)

YELLOW(26)

985-4530NA

Switch

Box

P4

32365A

J21

P21

Interlock

Connection

VEHICLE SECURE 12V INPUT 

LIFT STOWED / NOT STOWED SIGNAL 

(Located in cavity #5, #7 or #9 - see chart above)

32639A

32638A

GRA Y  / RED(18 )

BROWN(20)

NOT USED 

NOT USED 

NOT USED 

NOT USED 

6

5

4

3

2

1

COLOR

NO.

9-COND WIRE CODE 

WHITE(20)

NOT USED 

BLACK(20)

9

8

7

GRAY / RED(18)

LIFT NOT STOWED GROUND SIGNAL

NOT USED 

NOT USED 

NOT USED 

NOT USED 

6

5

4

3

2

1

COLOR

NO.

9-COND WIRE CODE 

NOT USED 

LIFT 12V OUTPUT

LIFT STOWED GROUND SIGNAL

9

8

7

1 2 3

4

5 6

7

8 9

1

2

3

4

5

6

7

8

9

YL/LT. BU(18) 

 GY/RD(18) 

UNFOLD

FOLD

DOWN

UP

WHITE(20)

GREEN(20)

RED(20)

BLACK(20)

4

3

2

1

COLOR

NO.

6-COND WIRE CODE

4

3

2

1

COLOR

NO.

6-COND WIRE CODE

1 2 3

4

5 6

BK(20)

RD(20)

Stow Interlock (+)

Microswitch

C-H

COM

NO

NC

C5

N.O.

COM.

N.C.

GN(20)

WH(20)
BN(20)

915-4539NA

Stow Interlock (-)

Microswitch

C-H

COM

NO

NC

C6

N.O.

COM.

N.C.

P31

WHITE(20)

 LT. GREEN(20) 

NOT USED

BROWN(20)

6

5

6

5

NOT USED

BROWN(20)

FUSE HOLDER(16)

BLACK(20)

3

2

1

5

4

6

In-Line

Fuse

J31

Summary of Contents for NCL Century 04 Series

Page 1: ...P O Box 310 Winamac IN 46996 USA 1 800 THE LIFT 574 946 6153 FAX 574 946 4670 WARNING Read manual before installing or servicing lift Failure to do so may result in serious bodily injury and or proper...

Page 2: ...Y REGISTRATION CARDS MUST BE RETURNED TO THE BRAUN CORPORATION OWNER STATE ZIP Sample Warranty Registration Card Two Braun Serial No Series No identi cation tags shown below are posted on the lift One...

Page 3: ...5 LCD Error Codes 6 Maintenance and Lubrication Schedule 7 11 Lift Electrical Schematic 12 Lift Wiring Diagram 13 Hydraulics Hydraulic Schematic 14 Notes 15 Hydraulics Parts List 16 Hydraulics Diagra...

Page 4: ...rails 2 Outer Barrier Automatic Outboard Roll Stop Rotating Pivot Slide Arms 2 Platform Pivot Arms 2 Pump Side Vertical Arm Bottom Parallel Arms 2 Platform Lights Outboard Right Lift Tite Latches 2 Un...

Page 5: ...k 2 Refer to the interlock installation instructions The platform will not fold stow when occupied 1 Position the platform at the floor level loading position 2 Loosen the locknut on the dual relief v...

Page 6: ...f the threshold area is occupied when the platform is at least 1 below floor level 1 Remove the threshold warning plate 2 Verify the threshold strip switch connectors are connected see illustration on...

Page 7: ...or image for right front pump lifts Inboard Outboard Right Left IB Raised Magnetic Sensor 31030A45 IB Raised Magnet 30662 IB Occupancy Microswitch Assy 31643A Rotary Position Sensor 31194A Stow Micros...

Page 8: ...button is pressed LCD Lift Codes Listed below are codes that the lift controller outputs during lift operation The codes will be displayed on an LCD screen located on the lift control board inside th...

Page 9: ...ce and Lubrication Lubrication Diagram Handrail Pivot Pins 2 LO Parallel Arm Pivot Pins 8 LO Lift Tite Latches Tower Pivot Points 2 LO Lift Tite Latch Dampening Spring 2 springs 4 Points LO Parallel A...

Page 10: ...ifts exposed to severe conditions weather envi ronment contamination heavy usage etc may require inspection and maintenance procedures to be performed more often than specified Maintenance Indicator T...

Page 11: ...nents for wear or damage and for proper operation Inspect microswitches for securement and proper adjustment Make sure lift operates smoothly Apply Light Oil See Lubrication Diagram Apply Light Grease...

Page 12: ...asteners connections etc for wear damage or leakage Inspect parallel arms bushings and pivot pins for visible wear or damage Inspect parallel arm pivot pin mounting bolts 8 Inspect platform pivot pin...

Page 13: ...n lubrica tion and maintenance procedures at 750 cycle intervals Consecutive 750 Cycle Intervals Decals and Antiskid Maintenance and Lubrication Schedule 4500 Cycles Replace decals if worn missing or...

Page 14: ...K 2 1 2 1 NO NC C BU 16 BU 16 BU 16 LIFT POWER SWITCH 2 1 P6 4 3 5 6 BK 24 GA COPPER BK 24 GA COPPER BK WH 24 GA SILVER BK WH 24 GA SILVER 1 2 1 2 P32 J32 RD RD BK BK GN GN WH WH 6 8 3 7 P13 4 5 2 1 6...

Page 15: ...RED 20 ORANGE 20 3 2 1 COLOR NO 3 COND WIRE CODE 1 2 1 2 3 2 1 1 2 3 GREEN 26 RED 26 YELLOW 26 3 2 1 COLOR NO 3 COND WIRE CODE GREEN RED ORANGE 3 2 1 COLOR NO 3 COND WIRE CODE 3 2 1 1 2 3 BLACK To FS...

Page 16: ...ding Relief Valve Lifting Relief Valve Fixed Displacement Pump Vented Reservoir Backup Pump Single Acting Cylinder Check Valve Manual Shutoff Valve 2 Way 2 Position Solenoid Valve Pressure Compensated...

Page 17: ...Page 15 NOTES This page intentionally left blank to provide a place for notes and references...

Page 18: ...Cap Reservoir Filler Screw On 30167 18 1 Fitting 90 1 8 NPT x 1 8 Barb Plastic 87563 19 1 Connector Plastic Y 1 8 O D 18877 20 1 Hose Thermal Plastic Black 1 8 I D 23742R 6 21 1 Handle with Grip 1720...

Page 19: ...Page 17 27 Opposite Pump Cylinder Manual Backup Pump 24 25 21 12 15 27 23 22 30 19 1 16 6 13 29 28 Hydraulic Pump Motor Pump Side Cylinder 10 7 17 20 18 28 26 26 14 2 3 5 4 Hydraulics Diagram...

Page 20: ...ooth 16368 32 1 Beeper Continuous 30487 33 1 Wire Assembly Lift Interlock Connection 32639A 34 1 Wire Assembly Lift Stowed Connection 32638A 35 1 Plate Backing Mounting Rear 985 2501RN 36 1 Pump Handl...

Page 21: ...21 22 6 7 9 20 2 11 4 3 UNFO LD FO LD DOW N UP 323 53 Pump Mounting Bolts Apply red 271 Thread Locker Locktite to the three pump mounting bolts items 28 and 29 if a blue nylon patch is not present on...

Page 22: ...Front 917 0457NA 175 4 Washer Thrust 875 O D 50 I D 0585T 29371 176 2 Screw 1 4 20 x 3 4 BHSCS 18 8 SS 81068 000 177 1 Slide UHMW Platform Rotate 31677 178 2 Rivet Pop 3 16 13 25 SD64BS 11513 179 2 B...

Page 23: ...59 99 20 80 129 144 161 160 159 157 156 157 158 154 110 68 98 97 124 130 60 91 91 152 91 152 87 86 91 90 170 94 89 177 119 19 66 76 75 93 94 45 45 148 148 148 141 85 88 57 57 60 148 60 147 22 60 82 15...

Page 24: ...Page 22 NOTES This page intentionally left blank to provide a place for notes and references...

Page 25: ...Over 300 Braun Dealers Worldwide Providing Access to the World Providing Access to the World International Corporate Hdqrs P O Box 310 Winamac IN 46996 USA 1 800 THE LIFT 574 946 6153 FAX 574 946 4670...

Page 26: ...t be provided when filing a warranty claim or ordering parts Return Authorization Procedure The Braun Corporation of Winamac Indiana warrants that it will repair or replace at Braun s sole option any...

Reviews: