Page 16
Before
pressing the orange
FOLD (In) switch to fold the
platform to the stowed position,
the lift operator
must
press the
red UP switch to
be certain
the
platform is in the
fully raised
position. The platform must be
in the fully raised position
before the platform can be
folded.
The lift operator should continue
to press the orange FOLD (In)
switch until the actuator ratchets
(makes audible clicking) when
folding the platform to the
stowed position to
ensure
the
lift is fully stowed.
Bridge Plate:
The bridge plate
assembly consists of the striker
back and the bridge plate flap.
The independent hinged bridge
plate flap bridges the gap
between the lift platform and the
vehicle floor when the platform
is positioned at floor level,
providing a surface for wheel-
chair (or standee) travel.
The bridge plate unfolds (ro-
tates) from the stowed position
Lift Features
(continued)
L200UARS Series lifts unfold
and fold at a position above
floor level (fully raised). The lift
attendant (operator) must
position (lower or raise), and
stop the platform at vehicle floor
level when a passenger is
entering or exiting the vehicle.
The platform must be properly
positioned at a height such that
Pre-Lift Operation Notes and Details
to the bridging (horizontal)
position as the lift platform
unfolds and vice versa. The
bridge plate flap rests on the
platform when deployed
(unfolded).
Read warning
posted on opposite page.
Discontinue lift operation
immediately if the bridge
plate does not operate
properly
.
Striker Back Bridge Plate Flap