Product specifications

Displayed temperature range: 

93.2 – 108 °F  

(34 – 42.2 °C) 

 

Operating ambient temperature range: 

50 – 104 °F  

(10 – 40 °C)  

  

Storage temperature range: 

-13 – 131 °F 

(-25 – 55 °C)   

Operating and storage relative humidity: 

10-95% RH (non condensing) 

Display resolution:  

0.1 °F or °C 

Accuracy for displayed temperature range

   

Maximum Laboratory Error 

35  –  42 °C (95  –  107.6 °F):  

±0.4 °F  

(±0.2 °C)  

Outside this range:  

±0.5 °F  

(±0.3 °C)   

Clinical repeatability:  

±0.26 °F  

(±0.14 °C)   

Reference Body Site: Oral Equivalent 

Battery life:   

2 years / 350 measurements  

Service life:   

5 years

This thermometer is specified to operate at 1 atmosphere or at altitudes with an atmospheric pressure up to 

1 atmosphere (700 - 1060 hPa).

Consult Instructions for Use

Type BF Applied Part

10 °C

40 °C

Operating temperature

Keep dry

Storage temperature

 

Subject to change without notice.
This appliance conforms to the following standards: 
This infrared thermometer meets requirements established in ASTM Standard (E 1965-98) as it pertains to 

infrared thermometers. Full responsibility for the conformance of this product to the standard is assumed by 

Kaz USA, Inc. ASTM laboratory accuracy requirements in the display range of 98 to 102 °F (37 to 39 °C) for IR 

thermometers is ±0.4 °F (±0.2 °C), whereas for mercury in- glass and electronic thermometers, the 

requirement per ASTM Standards E 667-86 and E 1112-86 is ±0.2 °F (±0.1°C).
EN ISO 80601-2-56: - Medical electrical equipment - Part 2-56: Particular requirements for basic safety and 

essential performance of clinical thermometers for body temperature measurement.
EN IEC 60601-1: Medical electrical equipment – Part 1: General requirements for basic safety and essential 

performance.
EN ISO 14971: Medical devices – Application of risk management to medical devices.
EN ISO 10993-1: Biological evaluation of medical devices – Part 1: Evaluation and testing within a risk 

management process.
EN IEC 60601-1-2: Medical electrical equipment – Part 1-2: General requirements for basic safety and 

essential performance – Collateral standard: Electromagnetic compatibility – Requirements and tests.
EN ISO 15223-1: - Medical devices. Symbols to be used with medical device labels, labelling and information 

to be supplied. General requirements.
EN IEC 60601-1-11: Medical electrical equipment – Part 1-11: General requirements for basic safety and 

essential performance – Collateral standard: Requirements for medical electrical equipment and medical 

electrical systems used in the home healthcare environment.
This product conforms to the provisions of the EC directive 93/42/EEC.
MEDICAL ELECTRICAL EQUIPMENT needs special precautions regarding EMC. For detailed description of 

EMC requirements please contact your authorized local Service Center (See guarantee card).
Portable and mobile RF communications equipment can affect MEDICAL ELECTRICAL EQUIPMENT.

Please do not dispose of the product in the household waste at the end of its useful life. 

To protect the environment, dispose of empty batteries at appropriate collection sites according to 

national or local regulations. 

English

Attention, consult 

accompanying documents

Limited three year warranty

 

You should first read all Instructions before attempting to use this product.

A.  This 3 year limited warranty applies to repair or replacement of product found to be defective in 

material or workmanship. This warranty does not apply to damage resulting from commercial, abusive, 

unreasonable use or supplemental damage. Defects that are the result of normal wear and tear will not 

be considered manufacturing defects under this warranty. 

KAZ IS NOT LIABLE FOR INCIDENTAL OR 

CONSEQUENTIAL DAMAGES OF ANY NATURE, ANY IMPLIED WARRANTY OF MERCHANTABILITY 

OR FITNESS FOR A PARTICULAR PURPOSE ON THIS PRODUCT IS LIMITED IN DURATION  TO THE 

DURATION OF  THIS WARRANTY.

 Some jurisdictions do not allow the exclusion or limitation of 

incidental or consequential damages or limitations on how long an implied warranty lasts, so the above 

limitations or exclusions may not apply to you. This warranty gives you specific legal rights, and you 

also may have other rights which vary from jurisdiction to jurisdiction. This warranty applies only to the 

original purchaser of this product from the original date of purchase.

B.  At its option, Kaz will repair or replace this product if it is found to be defective in material or 

workmanship.

C.  This warranty does not cover damage resulting from any unauthorized attempts to repair or from any 

use not in accordance with the instruction manual.

Call us toll-free at 1-800-477-0457 or e-mail:  [email protected]

Please be sure to specify a model number.

NOTE: IF YOU EXPERIENCE A PROBLEM, PLEASE CONTACT CONSUMER RELATIONS FIRST OR SEE  

YOUR WARRANTY. DO NOT RETURN THE PRODUCT TO THE ORIGINAL PLACE OF PURCHASE.  DO 

NOT ATTEMPT TO OPEN THE THERMOMETER HOUSING YOURSELF, DOING SO MAY VOID YOUR 

WARRANTY AND CAUSE DAMAGE TO THE PRODUCT OR PERSONAL INJURY.

Summary of Contents for IRT6520BUS

Page 1: ...i...

Page 2: ...7226 Envoyer un courriel ConsumerRelations HelenofTroy com Visiter BraunHealthcare com Certaines marques de commerce utilis es sous licence deThe Procter Gamble Company ou ses soci t s affili es Therm...

Page 3: ...f less than 37 weeks Small for gestational age is defined as a a newborn baby birth to 4 weeks of age born at 37 weeks or later with a weight below the 10th percentile for babies of the same gestation...

Page 4: ...to measure core body temperature2 which is the temperature of the vital organs Ear temperatures accurately reflect core body temperature 3 since the eardrum shares blood supply with the temperature c...

Page 5: ...on beep indicates that an accurate temperature measurement has been taken The result is shown on the display 0 3 3 36 36 Months 0 3 3 36 36 Months 0 3 3 36 36 Months For the next measurement press Eje...

Page 6: ...nal or local regulations Calibration The thermometer is initially calibrated at the time of manufacture If this thermometer is used according to the use instructions periodic re adjustment is not requ...

Page 7: ...ical electrical equipment and medical electrical systems used in the home healthcare environment This product conforms to the provisions of the EC directive 93 42 EEC MEDICAL ELECTRICAL EQUIPMENT need...

Page 8: ...ed below The customer or the user of the IRT6520 should ensure that it is used in such an environment The IRT6520 equipment is intended for use in the electromagnetic environment specified below The c...

Page 9: ...otez la fourchette de temp ratures ThermoScan habituelle pour la personne concern e titre d indication suppl mentaire cran code couleur Age PrecisionMC Les recherches cliniques montrent que la d finit...

Page 10: ...cal Physiology W B Saunders Philadelphia 1996 pp 754 5 4 Netter H F Atlas of Human Anatomy Novartis Medical Education East Hanover NJ 1997 pp 63 95 2 Appuyez sur le bouton marche arr t Pendant un auto...

Page 11: ...l oreille non trait e si des gouttes auriculaires ou d autres m dicaments pour l oreille ont t introduits dans le conduit auditif Utilisez l oreille vers le haut si la personne tait couch e sur le c t...

Page 12: ...t le POUR LE CANADA SEULEMENT Le CODE DE DATE situ dans le compartiment des piles indique la date de fabrication Les trois 3 premiers chiffres apr s le CODE DE DATE repr sentent la date julienne du jo...

Page 13: ...e l environnement jetez les piles usag es dans des centres de collecte adapt s conform ment aux r glementations nationales ou locales Garantie Carte Consommateur disponible sur notre site http www hot...

Page 14: ...ique Directives et d claration du fabricant missions lectromagn tiques ENVIRONNEMENT DOMESTIQUE OU M DICAL Ph nom ne Test d missions Norme ou m thode de test CEM de base NNIVEAUX DES TESTS D IMMUNIT D...

Page 15: ...nfermedad cr nica recuperando de cirug a Receptor de trasplante por ejemplo h gado coraz n pulm n ri n Este term metro contiene piezas peque as que pueden ser tragadas o producir peligro de asfixia pa...

Page 16: ...do gotas u otro medicamento para los o dos en el conducto auditivo Utilice el o do que ha estado hacia arriba si el individuo ha estado acostado de lado con un o do hacia abajo sobre una almohada Espa...

Page 17: ...ECHA ubicado dentro del compartimiento de la bater a Los primeros tres 3 d gitos despu s del C DIGO DE FECHA representan la fecha Juliana en la que el producto fue fabricado y los siguientes dos 2 d g...

Page 18: ...1 11 Equipos electrom dicos Parte 1 11 Requisitos generales para la seguridad b sica y el funcionamiento esencial Est ndar colateral Requisitos para equipo electrom dico y sistemas electrom dicos util...

Page 19: ...iaconel presentemanual Ll menosladagratuitaal 1 800 477 0457 CorreoElectr nico ConsumerRelations HelenofTroy com Porfavoraseg resedeespecificareln merodemodelo NOTA SITIENEPROBLEMAS PORFAVORLLAMEPRIME...

Page 20: ......

Page 21: ...3JUL20 50 matte text Revision 4 Release Date Date 01JUL20 Scale 1 1 Rerelease Date Colors Special Instructions Dielines Do not print Cyan 0 Coating Overall Gloss Varnish Spot UV Magenta 0 Yellow 0 Bla...

Reviews: