Page 23
MAINTENANCE and LUBRICATION
Proper maintenance is necessary to ensure safe,
trouble-free operation. Inspecting the ramp for
any wear, damage or other abnormal conditions
should be a part of the transit agency daily service
program. Simple inspections can detect potential
problems.
Preventive maintenance visual inspections do not
WDNHWKHSODFHRIWKHSURFHGXUHVVSHFLÀHGLQWKLV
schedule.
The maintenance and lubrication procedures
VSHFLÀHGLQWKLVVFKHGXOHPXVWEHSHUIRUPHGE\
a Braun authorized service representative at the
scheduled intervals according to the number of
F\FOHVRUHODSVHGWLPHZKLFKHYHUFRPHVÀUVW
RA300 Series ramps are equipped with hardened
pins and self-lubricating bearings to decrease
wear, provide smooth operation and extend the
service life of the ramp.
When servicing the ramp at the consecutive
recommended intervals, inspection and lubrica-
WLRQSURFHGXUHVVSHFLÀHGLQWKHSUHYLRXVVHFWLRQV
should be performed (repeated). Clean compo-
nents and the surrounding area before applying
lubricants. LPS2 General Purpose Penetrating
Oil is recommended where Light Oil is called
out. Use of improper lubricants can attract dirt or
other contaminants which could result in wear or
damage to the components. Ramp components
exposed to contaminants when lowered to the
JURXQGPD\UHTXLUHH[WUDDWWHQWLRQ6SHFLÀHG
lubricants are available from The Braun Corpora-
tion (part numbers provided).
Maintenance and lu-
brication procedures
must be performed
DVVSHFLÀHGE\DQ
authorized service
technician.
Failure to do so may
result in serious
bodily injury and/or
property damage.
All listed inspection,
lubrication and main-
tenance procedures
should be repeated at
750 cycle intervals fol-
lowing the scheduled
1500 cycle mainte-
nance procedures.
These intervals are a
general guideline for
scheduling mainte-
nance procedures and
will vary according to
ramp use and condi-
tions.
Ramps exposed to severe conditions (weather,
environment, contamination, heavy usage, etc.) may
require inspection and maintenance procedures to
EHSHUIRUPHGPRUHRIWHQWKDQVSHFLÀHG
Cycle Counter: RA300 Series ramps are equipped
with a cycle counter located in the pan weldment.
This cycle counter allows the service technicain to
track the number of cycles.
Discontinue ramp use immediately if maintenance
and lubrication procedures are not properly per-
formed, or if there is any sign of wear, damage or
improper operation. Contact your sales represen-
tative or call The Braun Corporation. One of our
national Product Support representatives will direct
you to an authorized service technician who will
inspect your ramp.
750
Cycles
Inboard ramp hinge
Outboard ramp hinge
Drive arm pivot pins (screws, nuts and bearings)
Drive arm and cam gear pivot shaft
Clean and lubricate. Apply Light Oil - See
Lubrication Diagram
Clean and lubricate. Apply Light Oil - See
Lubrication Diagram
Apply Light Oil - See Lubrication Diagram
Apply Light Oil - See Lubrication Diagram
continued
Maintenance and Lubrication Introduction
Maintenance and Lubrication Schedule
Summary of Contents for BF3248Y-2
Page 21: ...Page 19 BLANK for LAYOUT...