18
B 3 HOT
ENGLISH
magnetic outside rotor (see figure 11).
figure 11
7
Push the bowl towards the rear wall of the
unit until it fits snugly around the gasket and its
front fastening hooks are properly engaged (see
figure 12).
figure 12
8
Use fresh product to chase any remaining
sanitizer from the bottom of the bowl(s). Drain
this solution. Do not rinse out the machine.
5. 6 IN-PLACE SANITIZATION
The In-Place Sanitization prior to starting the
machine may be performed, if needed, only as
further precaution, in addition to the
Disassembled Parts Sanitization described
before, but never in lieu of it.
1
Prepare two gallons of a warm (45-60°C,
120-140 °F) sanitizing solution (100 PPM
available chlorine concentration or 1 spoon of
sodium hypoclorite diluted with 2 liters of water)
according to your local Health Codes and
manufacturer’s specifications.
2
Pour the solution into the bowl(s).
3
Using a brush suitable for the purpose, wipe
the solution on all surfaces protruding above the
solution-level and on the underside of the top
cover(s).
4
Install the top cover(s) and operate the unit.
Allow the solution to agitate for about two
minutes. Drain the solution out of the bowl(s).
5
Use fresh product to chase any remaining
sanitizer from the bottom of the bowl(s). Drain
this solution. Do not rinse out the machine.
6 ROUTINE MAINTENANCE
1
Daily:
inspect the machine for signs of
product leaks past seals and gaskets. If proper
assembly does not stop leaks around seals or
gaskets, check for improper lubrication, worn or
damaged parts. Replace parts as needed.
2
In case of noise it needs to unplug the cooler
and call for service.
3
In case of failure unplug the machine,
because unexpected start again would be
possible.
4
It needs to fix everything back in the initial
position after any repairmen, like screws and
covers.
6. 1 MAINTENANCE (TO BE
CARRIED OUT BY QUALIFIED
SERVICE PERSONNEL ONLY)
1
Monthly:
remove the dust from the
condenser. To do this unplug the unit.
2
Annually:
remove the panels and clean the
inside of the machine including the base, side
panels, condenser, etc.
3
Annually:
Check if the auger bushings are
worn out or ovalized. If they are, replace them
with new ones.
4
Never remove the insulating jacket from
around the suction tubing of the evaporator (the
copper tubing located on the right side of gear
motor). In case the insulating jacket is missing
replace the entire parts with original spare parts
from the supplier.
ATTENTION
Before any disassembly and/or cleaning
procedure make sure that the dispenser is
disconnected from its power source by
unplugging it.