Chart 3.6
Tube Installation Sequence, Baffle Location and Secured Joints for Reflectors
30 Foot
40 Foot
Burner Control Box
w/16 in. Burner Tube
Key
Expansion Joint on
Reflectors
Secured Joint on
Reflectors
Primary Combustion
Chamber with Clamp
Radiant Tube
Exchanger with Clamp
Baffle Location
Secure vent material to exchanger with three #8
sheet metal screws. Seal with high temperature
silicone sealant. Do not use tube clamp.
27
DX3
Series
20 Foot
Final Heater Assembly
3.0
Installation
•
Final Heater Assembly
50 Foot
60 Foot
70 Foot
Stainless steel clamp on 150,000 to 200,000 BTU/h models (P/N: TP-220).
Stainless steel clamp on 150,000 to 200,000 BTU/h models (P/N: TP-220).
Stainless steel clamp on 150,000 to 200,000 BTU/h models (P/N: TP-220).
Stainless steel clamp on 150,000 to 200,000 BTU/h models (P/N: TP-220).
Stainless steel clamp on 150,000 to 200,000 BTU/h models (P/N: TP-220).
80 Foot
0° Mounting Angle
1 to 45° Mounting Angle
NOTE:
When securing joints on reflectors
which are rotated on an angle from horizontal,
secure joint only on top side of reflector to allow
for sufficient heater expansion and contraction.