S83/85 Ultrasonic Generator
Options
A40-064 Rev 0
Page 92
7.3
OEM-I/O Board – 101-063-503
7.3.1
General
The 101-063-503 OEM I/O kit enables the ultrasonics to be turned on remotely by means
of a switch, plc or relay. It also provides a signal that indicates that the ultrasonics are
operating.
This option may be used with S8000, S8300 or S8500 power supplies.
7.3.2
Kit Components
OEM I/O Board (100-242-324)
Ribbon Cable
Ground Wire
Terminal Block
Hardware
M3 x 25 screw
M3 nut
M3 Internal toothed washer
#6 flat washer
Plastic spacer
M4 nut
M4 flat washer
M2.5 x 8 screw
Qty 2
M2.5 split washer
Qty 2
7.3.3
Installation
Warning:
Be certain power is off and the power supply is unplugged before
beginning the installation. The installation should only be performed by
qualified personnel.
Reference Figure 7-9 for hardware installation and locations.
Remove the power supply’s top cover.
Attach the supplied ground wire to the ¼ inch GND tab located at the corner of the I/O
board.
Attach and lock into place the supplied two wire harnesses to the I/O board’s header J21.
Attach and lock into place the supplied ribbon cable to the I/O boards header J8.
Place the I/O board into the power supply so that the I/O board’s four position header J2
extends through the cutout at the back of the power supply.
Secure the I/O board to the back panel by installing the two M2,5 screws and split
washers through the power supply’s back panel and into the I/O boards metal bracket.
Secure the I/O board to the side panel by installing the supplied M3 x 25 screw, #6 flat
washer, plastic spacer, M3 internal tooth washer and M3 nut.
Secure the I/O board’s ground wire ring tongue terminal to the power supply’s chassis
M4 stud with the supplied M4 flat washer, M4 split washer and M4 nut in that order.
Summary of Contents for S83
Page 2: ......
Page 10: ......
Page 12: ......
Page 72: ......
Page 74: ......
Page 82: ...S83 85 Ultrasonic Generator Options A40 064 Rev 0 Page 82 S83 85 Ultrasonic Generator A40 064 ...
Page 95: ...S83 85 Ultrasonic Generator Options A40 064 Rev 0 Page 95 Figure 7 12 OEM I O Installation ...
Page 98: ......
Page 100: ......
Page 104: ...S83 85 Ultrasonic Generator Assistance A40 064 Rev 0 Page 104 ...