S83/85 Ultrasonic Generator
System Installation
A40-064 Rev 0
Page 52
5.8.3
Mounting FC Junction Boxes
Figure 5-12 contains an illustration shows two FC-type immersible transducers mounted on a
stainless steel rack and connected to junction boxes.
Figure 5-16 FC Type Immersible Transducer Junction Box Mounting
Rack
FC-type
immersible
transducer
Flanged Junction
Box
Flexible Cable
4 inch minimum
radius
Jumper Cable
Note:
You can also wire the two immersible transducers into one junction box. (Refer to
Configuration Diagrams
).
Step
Action
1
Select a location for the immersible transducer. (Refer to
Installation Do’s and Don’ts
).
2
Measure and mark the four places for installing weld studs.
3
Mount the immersible transducer to the tank or rack.
4
Route the flexible cable to the corresponding junction box. Note:
The min. bend radius of the flexible cable is 4 inches in diameter.