5.11.2
Mounting an EB-Type Immersible Transducer
Figure 5-32 Mounting an EB Type Immersible Transducer
EB-type Immersible
Transducer
#10-32 Weldstuds
Nuts and Washers
EB Style
Junction Box
Jam Nut and
Washer
RF Cable
Tank Wall
13/16" Dia.
Hole in tank
To mount an EB-Type immersible transducer, follow these steps:
Step
Action
1
Select a location on the tank bottom or sidewall for the immersible
transducer.
2
Locate and punch or drill the mounting hole
3
Attach the immersible transducer to the tank bottom or sidewall (as
shown in Figure 5-32) as follows:
a. Attach the washer and jam nut to the fitting and
tighten.
b. Route the fitting with the wires through the hole in
the back of the EB/SB junction box.
c. Attach the washer and jam nut to the fitting, and
tighten.
d. Secure the Immersible to the bottom or wall with
weldstuds, nuts and washers.
4
Connect the wires to the incoming RF cable or jumper from another
immersible transducer. Follow the wiring instructions.