Connection of drain hoses
●
In sert the d rain hos e into a drain pip e wi th a mini mum dia met er o f 40m m, or le t it run in to the si nk, m aki ng s ure
to avoid bendin g or crim ping it. The heig ht o f the drain pip e m ust be less than 1000 mm .
A
Counter
Front
Drain pipe
NOTE
The top of the hose
must be less than
1000mm.
φ
40mm
B
Tension adjustment
of the door spring
【
】
Figure5
Tension adjustment of the door spring
●
The door springs are set at the factory to the proper tension for the outer door.
If aesthetic wooden panel are installed, you will have to adjust the door spring tension.
Rotate the adjusting screw to drive the adjustor to strain or relax the steel cable
(see figure 5).
D oo r spri ng tensi on is c orrect when
t he doo r remains horiz ontal i n t he
f ul ly o pened posit ion
y et rises
t o a cl os e w ith t he sl ight lift of a
f inger.
,