11
CASE OF FLUSH MOUNTING
ABOVE A DRAWER, A
CUPBOARD OR AN OVEN
(continued)
—
Above an oven
(Fig. 01)
This must be
in a low position
. At the
front there must be a 0.5 cm opening
around the cabinet’s width and an air inlet
of 30 cm
2
minimum at the back of the unit.
If the oven is not fitted with a ventilation
system with an air outlet at the front, you
must use an insulation kit between the
oven and the hob (to be ordered from the
distributor).
If the oven has a “pyrolysis” function,
NEVER
use the cooking hob during pyrolysis.
;;;;
11 cm
mini
Découpe de
30 cm
2
à droite
et/ou à gauche
Ouverture min.
100 cm
2
Circulation d'air ambiant
6 cm
5 cm
Circulation d'air chaud
1
3
;
11 cm
mini
Fig. 01
Min. 0.5 cm opening
around the hob’s width.
•
Min.100 cm
2
opening
Circulation of ambient air
Circulation of hot air
30 cm
2
cut-
out on the
right or the
left
1/ INSTALLING YOUR APPLIANCE
EN