background image

INTRODUCTION 

 

OPA-100 

INTRODUCTION           3/22       MS0100-06-0_service_manual.doc 

 

1  INTRODUCTION 

 

1.1  CONTENTS OF THE MANUAL  

 
This manual is for the TECHNICAL SERVICE department and is an aid for repair and servicing of the 
OPA Diesel Smokemeter. 
 
The manual is made with different chapters: 
 
Chapter 2 

SAFETY GENERAL INFORMATION 

 
Chapter 3 

INSTALLATION AND SERVICE OPERATIONS 

 
Chapter 4 

TECHNICAL DOCUMENTS 

 
Chapter 5 

OTHER INFORMATION 

 
 
 

________________________________________ 

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

 

Summary of Contents for OPA-100

Page 1: ...SERVICE MANUAL TECHNICAL INFORMATION REV 1 0 SMOKEMETER OPA 100...

Page 2: ...10 3 3 6 1 Filter 10 3 3 6 2 Opacity calibration procedure 11 3 4 SUBSEQUENT VERIFICATION 12 3 5 ROUTINE TESTING 12 4 TECHNICAL DOCUMENTS 13 4 1 A SYSTEM OVERVIEW 13 4 2 INTERNAL CABLES 14 4 2 1 Cable...

Page 3: ...or the TECHNICAL SERVICE department and is an aid for repair and servicing of the OPA Diesel Smokemeter The manual is made with different chapters Chapter 2 SAFETY GENERAL INFORMATION Chapter 3 INSTAL...

Page 4: ...d All operations described in this manual must be done by trained people In order to move heavy loads or to use any tools it is compulsory to put on protection gloves In order to use tools drill saw i...

Page 5: ...nual doc 2 2 SYMBOL This paragraph explains all safety symbols you might find on the devices 2 2 1 SAFETY ALTERNATE CURRENT GROUND READ MANUAL INSTRUCTION ATTENTION ELECTRICAL SHAKE ATTENTION DON T RE...

Page 6: ...r 1 MGT 300 R RPM Counter radio transmission 1 IF 030 PC connection cable 1 OMNI 020 Connection cable PSI AGS OMNIBUS 4 m 1 CMNI 010 Connection cable PSI AGS OMNIBUS 0 4 m 1 TRO 030 AGS OPA trolley 1...

Page 7: ...INSTALLATION AND SERVICE OPERATIONS OPA 100 INSTALLATION AND SERVICE OPERATIONS 7 22 MS0100 06 0_service_manual doc 3 1 2 SYSTEM N 1 PC AGS 200 OPA 100 OPA 100 PSI 60 AGS 200 COM PC...

Page 8: ...TERNAL VISUAL CHECK Perform an external visual check The plates labels must be readable The seal must not be broken The eight screws of the cover must be present and fixed securely Verify that the sam...

Page 9: ...n autozero adjustment During the autozero adjustment the electro valve turn on and the two fans will start Check the fans turn properly The red led on the electronic board flashes 1 pulse sec to signa...

Page 10: ...DJUSTMENT Check if the automatic zero adjustment works properly Verify proper insertion of the frames in the chamber they must be all inserted Select F1 continuous test then press F2 to start with a z...

Page 11: ...ntil the autozero has finished Insert the calibration filter into the hole of the empty frame Insert the value of the filter into the box displayed on the display Press ENTER when ready and the automa...

Page 12: ...t term subsequent verification perform a filter calibration using the filter provided with OPA 100 For long term subsequent verification perform all tests included in the initial verification When the...

Page 13: ...d in this manual because in case of electronic failure cards must be replaced In this chapter there is just cable and the connection diagrams 4 1 A SYSTEM OVERVIEW Connection panel Smoke input Electro...

Page 14: ...4 2 INTERNAL CABLES 4 2 1 Cables View In the photo you can see 1 Cable 1240100017XX omniBUS 2 Cable 1240100016XX RS 232 3 Cable 1240100008XX RPM 4 Cable 1240100015XX temp prog Heating Resistor connec...

Page 15: ...4 Thermocouple cable 5 Tube T4S0205 from measurement chamber 6 124010001000 Cable for Led 1 124010001700 cable for Power supply 2 125010002400 cable Fan Receiver Side 3 124010001700 cable for RS485 ne...

Page 16: ...NICAL DOCUMENTS MS0100 06 0_service_manual doc 16 22 TECHNICAL DOCUMENTS 4 2 2 124010001700 Internal OMNIBUS cable for Power supply and RS485 network 4 2 3 124010001500 Internal cable for Temperature...

Page 17: ...TECHNICAL DOCUMENTS OPA 100 TECHNICAL DOCUMENTS 17 22 MS0100 06 0_service_manual doc 4 2 4 124010000800 Internal cable for RPM Piezo input 4 2 5 124010001600 Internal cable for RS232 Interface...

Page 18: ...TECHNICAL DOCUMENTS MS0100 06 0_service_manual doc 18 22 TECHNICAL DOCUMENTS 4 2 6 125010000900 Internal cable for antenna to receive from MGT 300 R 4 2 7 124010001000 Cable for Led of Chamber Light E...

Page 19: ...ICAL DOCUMENTS OPA 100 TECHNICAL DOCUMENTS 19 22 MS0100 06 0_service_manual doc 4 2 8 124010001100 Cable for Photodiode Chamber light receiver 4 2 9 124010000900 Internal cable for LM35 Chamber temper...

Page 20: ...OPA 100 TECHNICAL DOCUMENTS MS0100 06 0_service_manual doc 20 22 TECHNICAL DOCUMENTS 4 2 10 125010002400 Internal cable connected to Fan Side Emission Side Receiver...

Page 21: ...22 MS0100 06 0_service_manual doc 5 OTHER INFORMATION No other information available at the moment Auxiliary information will be made available by subseguent manual revision or service news or CD or W...

Page 22: ...OPA 100 OTHER INFORMATION MS0100 06 0_service_manual doc 22 22 OTHER INFORMATION Blank Page...

Reviews: