BRAILLO
l
B 650 SF
40
The Service/Diagnostic menu
Main Menu - Warning - Service/Diagnostic
When entering this menu choice, a warning window will appear.
The purpose of this warning is make the user aware that the safety
switches on the cover is now disabled. This is done to make it possible
to run smaller tests during service.
Please take care for the rotating parts!
The Printer may unexpectedly be started by other users!
To make sure you have absolutely control when doing service
with the power connected, please disconnect the computer
cables (Ethernet and USB).
Print demo text:
Main Menu - Warning - Service/Diagnostic - Warning - Print demo text
Prints a short demo text with the current settings.
Print Test Pattern:
Main Menu - Warning - Service/Diagnostic - Warning -
Print Test Pattern
When entering this menu choice, a warning window will appear.
This is to make the user aware that print jobs from the computer will
not be printed as long as you are in this sub-menu.
- X pattern.
Will print dots in a x pattern across the sheet,
useful when searching for missing dots.
- Full cell, single sided.
Prints all six dots on all characters on one side of the sheet,
useful for dot quality tests.
- Full cell, both sides.
Prints all six dots on all characters on both sides of the sheet,
useful for testing the paper quality.
- O/Ø pattern.
Prints a test pattern made of dot 1,3,5 and 2,4,6, single-sided, useful when searching for extra dots.
Cell spec:
Main Menu - Paper Layout - Cell spec
Here you can choose between the Marburg medium standard
or the US NLS standard Braille cell spacing.
Summary of Contents for 650 SF
Page 1: ...Rev April 2018 BRAILLO L NORWAY FOR BETTER BRAILLE AND MORE User s Guide BRAILLO 650 SF...
Page 2: ...2018 Braillo Norway AS...
Page 4: ...BRAILLO l B 650 SF 4...
Page 104: ...BRAILLO l B 650 SF 104 Frame complete...
Page 133: ...BRAILLO l B 650 SF 133 7 15 Complete schematic pneumatic...
Page 135: ...BRAILLO l B 650 SF 135 7 17 Schematic electrical 230V...
Page 137: ...BRAILLO l B 650 SF 137 7 19 Schematic PLC...
Page 139: ...BRAILLO l B 650 SF 139 7 21 Schematic sensors Picker pos Vacuum sensor...
Page 140: ...BRAILLO l B 650 SF 140 Folding ready Stackholder neg Output sensor...
Page 142: ...BRAILLO l B 650 SF 142 Door 1 switch Door 2 switch Stapling position analog sensor...
Page 143: ...BRAILLO l B 650 SF 143 7 22 Schematic staplers position 7 23 Schematic pneumatic valves...
Page 150: ...BRAILLO l B 650 SF 150 115 cm 77 cm 112 cm 8 5 Measurements All measurements in centimetres...
Page 151: ...BRAILLO l B 650 SF 151 9 GENERAL INFORMATION 9 1 Declaration of conformity...
Page 155: ...BRAILLO l B 650 SF 155...