24H.SYS.ALA.

“RES.24H.SYS.”

Generic notification of tamper alarm (sab-

otage).

X

ALARM 24H xx

RES..24H.ALA.xx

AREA DESCR.

When an input is in tamper state also the as-

sociated areas go into sabotage alarm mode.

All tamper-type events which are not as-

sociated to any inputs, automatically trig-

ger a tamper alarm of area 1.

X

REMOTE CONTROL xx

REMOTE CONTROL DESCR.

Each time you act on the system’s remote 

control, this is logged in the events log.

REMOTE N.xxx CODE

CODE DESCR.

Entering a code (e.g. user) from remote 

(either voice guide or sms) is logged in the 

events log.

X

TEC.ALLARM xx

RES.TEC.ALA. xx

AREA DESCR.

When an input goes into alarm mode also 

the associated areas go into technical 

alarm mode.

X

BURGLARY ALA. xx

RES.BURG.ALA.xx

AREA DESCR.

When an input goes into alarm mode also 

the associated areas go into burglary 

alarm mode.

X

ACTIV.CODE xxx

CODE DESCR.

Code xxx has been activated from the 

user menu. The chronologically previous 
event 

CODE N. xxx

  shows who has 

edited it.

DEACTIV.CODE xxx

CODE DESCR.

Code xxx has been activated from the 

user menu. The chronologically previous  
event 

CODE N. xxx

 shows who has 

edited it.

WRONG CODE

KEYPAD DESCR.

21 wrong codes have been inserted from 

keypads. The description is the one of the 

last keypad to have an insertion attempt.

X

INCORRECT KEY

INSERT. DESC.

21 invalid keys have approached insert-

ers. The description is the one of the last 

inserter to have an insertion attempt.

X

ERR.INS.COM.xxx

When an inserter fails to communicate 

with the control unit.          

X

INS.FORCE.COD.xxx

When the user forces switch on of the 

control unit during a system breakdown 

or anomaly.

EXCL.INP.TIME.XXX

RES.EXCL.INP.XXX

When an input xxx is momentarily excluded. 

SET DATE/TIME

When the clock is initialised from key pad 

or PC

TEL.CALL.OK XXX

When the User received a call from the 

control unit, press key 5 on the phone 

to receive notification of the message or 

KISS-OFF package received.

OUTPUT ON XXX

Output activation

OUTPUT OFF XXX

Output activation.

PSTN BREAKDOWN

PSTN BREAKDOWN RES.

When the line has been activated from 

the "Telephone Options" menu and is in 

breakdown status.

GSM BREAKDOWN 

GSM BREAKDOWN RES.

When the GSM function has been activated 

from the "Telephone Options" menu and is 

in breakdown status.

WRONG CODE

When an incorrect password has been in-

serted 5 times.

WRONG KEY

When an incorrect key has been attempted 

5 times.

Summary of Contents for Proxinet 8

Page 1: ...PROGRAMMING MANUAL SECURITY ALARM CONTROL UNIT English EN English EN...

Page 2: ...m INDEX 1 SYMBOLS AND GLOSSARY PAGE 2 2 TECHNICAL MENU PAGE 3 ACCESSING THE TECHNICAL MENU 3 2 1 PROGRAMMING MODE 3 MENU ITEMS BELONGING TO OTHER MODES 3 EASY MODE 4 STANDARD MODE 4 ADVANCED MODE 4 2...

Page 3: ...andard system parameters are available ADVANCED all configurable parameters are available Passing from Advanced to Easy means automatic reconfiguring of the parameters which will be hidden Following a...

Page 4: ...ed to the NIGHT TIME area From a positive with NIGHT area switched off U3 Fault yields a negative if faults are detected U2 System status yields a negative if at least one area is switched on U4 Techn...

Page 5: ...e set 0 4 KEYPADS Keypads Default F S A Use the keys to enable the keypads used Example if you want to use 4 keypads on the system set 0 4 INSERTERS MITHO TOUCH YES Inserters Default F S A Use the key...

Page 6: ...s INPUT TEST LAUNCH TEST AREAS TO TEST CRT U TAMP TEST LAUNCH TEST Control unit battery test F S A For promptly checking control unit battery status CRT U BATT TEST LAUNCH TEST SIRENS TEST LAUNCH TEST...

Page 7: ...IPADDR MODIF 255 255 255 000 NETMASK MODIF 192 168 001 001 GATEWAY MODIF IP COMPUTER PORT 36821 MODIF Network board automatic addressing A Enables disables auto addressing DHCP Keypad emulation PXWEB...

Page 8: ...ple a scenario that enables only perimetral PERIMETER ON OFF SEL AREAS Only the selected areas switch off nothing changes about the status of the non selected areas Example used when the user wants to...

Page 9: ...In this case the triggering of the alarm will inevitably warn that the system has been left with open inputs DEPENDENCY 01 Dependence Default A An area s dependence ties its switched on state to that...

Page 10: ...ted areas Cod 2 Employee associated areas SCENARIOS 01 CHANGE LIST Scenarios Default A sc 1 B sc 2 C sc 3 4 sc 4 S A Associates the scenarios to the keys on the keypad Use the arrow keys to select the...

Page 11: ...ING TO BED Scenarios Default L1 sc 1 L2 sc 2 L3 sc 3 S A Associate the scenarios to the three inserter LEDs Use keys to edit the scenario associated to the inserter led Example a home with three area...

Page 12: ...en FAULT It remains enabled with control unit engaged and disengaged The Fault Led light up for any malfunctions and breakdown output is enabled The system displays the ANOMALY message followed by the...

Page 13: ...s switch off Impulsive switching on off When input is unbalanced the associated areas exchange status when off they switch on and when on they switch off Stable switching on off When input is unbalanc...

Page 14: ...the associated areas are switched on and is delayed if partialised at least one area switched off and one switched on Example this parameter is set when it is necessary for the door to be delayed type...

Page 15: ...you can set this input Example two sensors point to the same room and the user wants an alarm to be issued when both sensors go into alarm mode INPUT 1 Type INSTANTANEOUS And input INPUT 2 INPUT 2 Ty...

Page 16: ...tput is commanded by the input s status More precisely the output is activated if the input is unbalanced and restored if the input is balanced ON ACTION 001 PULSE ON OFF Parameter viewable only if th...

Page 17: ...tion Default 000 S A Duration time of the impulsive output activation Example opening a door lock via code An impulsive output is associated to a code with a 3 second activation time IMPULSE TIME 001...

Page 18: ...t as a function of another output Example we want two outputs on the general alarm bus Output 10 type STABLE Output 21 type STABLE follows output OUTPUT 10 In the outputs Association menu assign gener...

Page 19: ...e Default 090 F S A Alarm time associated to technical type inputs BURGL ALARM 0 255 SEC 000 Burglary alarm time Default 000 F S A Alarm time associated to burglary type inputs BUZZER OUTPUT 01 0 255...

Page 20: ...gle areas A Telephone notifications associated to both activation and restoration of the single area s sabotage alarm the alarm is given by the inputs associated to the areas Use to select the areas U...

Page 21: ...AT FAILURE PHONE NOT MENU 05 TRN ON TRN OFF TOTAL SYSTEM ON Total switching on switching off and partialisation of the system F S A Telephone notifications associated to complete switching on complete...

Page 22: ...inserters Use to select the keys Use the keys to set the phone numbers ACT INP ALRM 001 Activating and restoring generic alarm of single inputs A Telephone notifications associated to both activation...

Page 23: ...ault NO S A For selecting the output to associate to the single area s ready status an area is deemed ready when none of its associated inputs is open AREA ON 01 NO Generic alarm area switched on Defa...

Page 24: ...om a PC is only allowed when the control unit is completely switched off i e no areas are switched on and the User code has been entered USER CODES CODE 001 USER 001 STATUS 001 ENABLED Clear code Defa...

Page 25: ...ED Activate Events item on user menu Default ENABLED A Activates code to accede to the Events item on the user menu EXTENS MENU 001 ENABLED Activate Extension item on user menu Default ENABLED A Activ...

Page 26: ...WITCH ON OFF A SWITCH ON OFF The key is activated to switch on and off the areas associated to it ONLY TURN ON The key is authorised only to switch on the areas associated to it Example for assigning...

Page 27: ...line Number to request the line from the pbx FORMAT 01 VOICE Telephone communication format Default see table at start VOICE The telephone communications will be of the voice type SMS The telephone c...

Page 28: ...with area switching off properties NONE Events such as general technical or sabotage alarms and so on trigger a cycle of phone calls this CANNOT be interrupted once it has started by neither codes nor...

Page 29: ...respond GSM RMT CTRL YES GSM SECURE YES ENABLE PHONES Activate control of PSTN line Default NO A If activated it checks control of the PSTN line if the line is down a breakdown notifications issued PS...

Page 30: ...PREVIOUS STATUS Quick switch on Default DISARMED A If activated it lets you start scenarios from the keypads without having to enter a code Warning When activated prevents exclusion of open inputs dur...

Page 31: ...g HH mm hour and minutes A action III address S status P extension To see the meaning of the values see the table below Example if programme step activates output 3 at 08 30 the following is displayed...

Page 32: ...r time is done automatically according to the Italian national rule 03 46 01 01 10 YEAR 10 Set date F S A Use the arrow key to select the parameters to edit and with the keys edit the value Press to e...

Page 33: ...eas man aged by the control unit the second de scription will read TOTAL whereas partial switching on will indicated the switched on areas example X PARTIALIS Areas switched on The partialisation even...

Page 34: ...pansion module on the bus xx has been tampered with Check module tamper X TAMP MOD RX xx MODULE DESCR The tamper of the radio receiver of bus xx has been tampered with Check module tamper X TAMP TASTI...

Page 35: ...xxx CODE DESCR Code xxx has been activated from the user menu The chronologically previous event CODE N xxx shows who has edited it WRONG CODE KEYPAD DESCR 21 wrong codes have been inserted from keyp...

Page 36: ...ents Under Article 3 2 Of The R Tte Directive EN 301 489 3 Electromagnetic Compatibility And Radio Spectrum Matters Erm Electromagnetic Compatibility Emc Standard For Radio Equipment And Services Part...

Reviews: