Example system diagrams (continued) 

 
 
If delegates are mainly to receive audio signals without making speeches themselves, a combination 
with the CSX4 control center and DIGIMIC CS units is a good choice.  
 
 
 
 

 

 
 

Summary of Contents for 05.0055

Page 1: ...Instruction manual DIGIMIC DCen MkII Central unit for DIGIMIC conference systems Article no 05 0055 ...

Page 2: ...able of contents Table of contents 2 About this guide 3 Symbols 3 General information 3 Important information 4 Safety instructions 4 Safety information 4 DIGIMIC Digital Conference System 6 System components 6 Software components 7 Declaration of Conformity 7 Structure 8 Introduction 8 Connections 8 Controls 9 Front 9 Back 10 Example system diagrams 13 Structure 15 Operation 16 Reset to DHCP 16 A...

Page 3: ...ating instructions Symbols The following means of representation are used in this manual Indicates instructions which if not followed may endanger your health the functionality of your device or the security of your data Indicates additional information and tips Texts in bold font and or underlined texts are texts or terms that should be highlighted General information Read this manual carefully a...

Page 4: ... or pinched particularly at plugs convenience receptacles and the point where they exit from the apparatus Only use attachments and accessories that are suitable according to the manufacturer Unplug the unit during lightning storms or when unused for long periods of time Have all maintenance work performed by qualified personnel Servicing is required when the equipment has been damaged in any way ...

Page 5: ...e uses spare parts that are approved by the manufacturer or have the same characteristics as the original parts The use of unsuitable spare parts may result in fire electric shock and other hazards Safety check After maintenance or repair of the device it is mandatory to perform a safety check to determine that the device is in a safe operating condition The DIGIMIC Conference System is state of t...

Page 6: ...ose of all individual components in accordance with local waste disposal regulations DIGIMIC Digital Conference System Thank you for choosing the DIGIMIC conference system You have invested in future proof conference technology DIGIMIC meets the requirements of studio technology and thus goes far beyond the original standard of conference technology The system can be configured via the software DC...

Page 7: ...retationManagement CameraControl AudioEventPlayer For more information on the Brähler software products and their operation please read the corresponding operating manuals Declaration of Conformity The DIGIMIC system complies with the standards ICE 914 ISO 4043 ISO 2603 DIN 56924 This equipment has been tested and found to comply with the limits for a Class A digital device pursuant to the Europea...

Page 8: ... Alternatively DDol interpreter consoles can be connected or combined with microphone units in separate chains As soon as a unit is connected to the central unit it is immediately ready for use without any further settings To adapt the setup to local conditions the DCen MkII central unit can be configured via the DCen ConfigTool software among other things you can use the software to select the mi...

Page 9: ...hone units Controls Front Status display The status display shows you the corresponding status for each line output left Power Power shows you the operating voltage on the respective line Green Power supply is proper Red there is an error e g short circuit the line is not supplied with power In case of failure of one power supply unit of a line the remaining line outputs can continue to be operate...

Page 10: ...tarts booting process Green DCen MkII is ready for operation Network connection Shows the status or connection to the network Yellow Link present Green Data is being transferred Back On Off switch Press the on off switch to turn the DCen MkII on or off Mains connection IEC connector C14 female panel connector for connecting the power supply via the supplied power cable line C13 connector The DCen ...

Page 11: ...UT socket Phoenix terminal In the audio matrix the signal routing for this output can be changed if required line level transformer balanced Line output jacks Out1 Out4 Audio signals are transmitted to external devices via four LINE outputs Phoenix terminal For example an external mixing console can be connected to these jacks to perform sound recordings or to route signals to a PA system In the a...

Page 12: ...dual chains can be extended by the DExt additional power supply for the operation of further DIGIMIC devices DDol interpreter consoles must not be connected in a chain together with other devices of the DIGIMIC family Otherwise the functionality cannot be guaranteed Never connect devices other than DIGIMIC microphone or interpreter consoles to these outputs The operating voltage could damage other...

Page 13: ...raehler systems com 05 0055 220223 V1 0 BRÄHLER Systems is constantly improving its products and therefore reserves the right to make technical changes without notice Example system diagrams In addition to CMic and SMic SChair units interpreter consoles are also connected to this DCen MkII The SMic SChair chain is extended by an additional DExt power supply unit ...

Page 14: ... BRÄHLER Systems is constantly improving its products and therefore reserves the right to make technical changes without notice In the following system example a DLine is interconnected in an SMic chain This allows external audio signals e g lectern to be integrated into the DIGIMIC system and controlled like a microphone console Further example system images can be found from page 20 of this manu...

Page 15: ...t of the DIGIMIC family to the DCen MkII Now connect the individual elements that you need for your conference All DIGIMIC components are connected to the central unit via the L1 L4 sockets Use suitable shielded CAT5e cables and RJ45 plugs DDol interpreter consoles must not be connected in a chain with other DIGIMIC devices The exception is the DExt auxiliary power supply When the DCen MkII is swi...

Page 16: ...m page 9 of this manual The DCen MkII is ready for immediate use in the factory settings Individual settings can be made using the DCen ConfigTool software All configurations are automatically saved by the DCen MkII and automatically recalled the next time it is switched on The DCen MkII is therefore ready for use after the first configuration in these settings even without a computer Alternativel...

Page 17: ...e DELegates delegate microphones DEL3 3 participants Max Number of active VIP microphones VIP3 Volume and conference mode LS volume 50 Conference operation AUT AUTN AUTF MAN AUT INTernal or EXTernal audio source INTERNAL Network menu Static and dynamic address assignment address assignment static or dynamic DYNAMIC TCP IP address Automatic Network Mask Automatic Default gateway Automatic SysLog Se...

Page 18: ...floor mix Number of output channels 64 32 languages 32 configurable channels Control Network connection TCP IP 100 MBit Connection of delegate units UNITS L1 L4 CAT5e cable 100 delegate units or more at four outputs or interpreter consoles at one output and delegate units at the other line outputs Extension of line outputs by means of DExt auxiliary power supply unit Equipment Power switch Power s...

Page 19: ...Set the power switch to the Power on position One or more of the yellow AF indicators of the DCEn MkII control panel are not lit L1 L4 Probably no audio signal is present no microphone active Check whether the speaker has activated the microphone illuminated ring on the microphone is lit Check the wiring of the units and the microphones One or more of the green voltage indicators 48 VDC of the DCe...

Page 20: ...aehler systems com 05 0055 220223 V1 0 BRÄHLER Systems is constantly improving its products and therefore reserves the right to make technical changes without notice Example system diagrams continued If delegates are mainly to receive audio signals without making speeches themselves a combination with the CSX4 control center and DIGIMIC CS units is a good choice ...

Page 21: ...ww braehler systems com 05 0055 220223 V1 0 BRÄHLER Systems is constantly improving its products and therefore reserves the right to make technical changes without notice In this example a DSwitch is integrated into the system The DSwitch protects the DCen MkII and switches to a back up device in the event of a fault Each DSwitch protects up to two DCen MkII ...

Page 22: ...ves the right to make technical changes without notice In this example CMic VIS ID with supporting audio functions for visually impaired conference participants is integrated in addition to CMic ID In this example a DPU is connected in between The DPU is an interface box that you use to connect delegate units to the Delegate App from Brähler Almost any touchscreen monitor can be connected to the D...

Page 23: ...com 05 0055 220223 V1 0 BRÄHLER Systems is constantly improving its products and therefore reserves the right to make technical changes without notice In this example application DIGIMIC multimedia units SMic123W and SMic133D are connected to the DCen MkII These allow for example viewing of documents relevant to the meeting Votes for example are made via the touchscreen display ...

Page 24: ...piaq IPK Irish GLE Italian ITA Japanese JPN Javanese JAV Kannada KAN Kanuri KAU Kashmiri KAS Kazakh KAZ Kikuyu KIK Kinyarwanda KIN Kirghiz KIR Kirundi RUN Klingon TLH Komi COM Congo CON Korean KOR Kurdish KUR Kwanyama KUA Laotian LAO Latin LAT Latvian LAV Limburgish LIM Lingala LIN Lithuanian LIT Luba Katanga LUB Luxembourgish LTZ Macedonian MAC Malagasy MLG Malay MAY Malayalam MAL Maltese MLT Man...

Page 25: ...s products and therefore reserves the right to make technical changes without notice If you have any questions about these operating instructions please contact BRÄHLER Systems GmbH Auf der Alten Burg 6 53639 Königswinter Germany T 49 2244 8414 4 sales braehler systems com www braehler systems com Note Changes or modifications to the equipment not expressly approved by Brähler Systems could void t...

Reviews: