Technical data
Digital audio
▪
48 kHz sampling frequency
▪
20 - 20,000 Hz frequency range
▪
Approx. 1 ms latency
▪
Low sensitivity to cell phones, Bluetooth, UMTS, WiFi, etc.
Audio interfaces
▪
1x OUT IN (Phoenix terminal)
▪
5x OUT (OUT and OUT 1to 4) (Phoenix terminal)
Configurable Ethernet switch for 4 Dante ports (Dante 1-4)
▪
4 port network switch
▪
Link speed: 1 GBps
▪
Sample Rate: 48 kBps/24 bit
▪
Number of DANTE input channels: 48 (32 lan 16 input channels (floor mix))
▪
Number of output channels: 64 (32 lan 32 configurable channels)
Control
▪
Network connection (TCP/IP), 100 MBit
Connection of delegate units
▪
UNITS L1 ... L4 (CAT5e cable)
▪
100 delegate units or more at four outputs or interpreter consoles at one output and delegate
units at the other line outputs
▪
Extension of line outputs by means of DExt auxiliary power supply unit
Equipment
▪
Power switch
▪
Power supply via USB
▪
4 green and 4 red LEDs for indication of operating voltage at L1 - L4
▪
4 yellow LEDs for audio signal at L1 - L4
▪
4 independent power supplies, 1 per output line
▪
4x5 audio matrix enables individual sound distribution
▪
Protection against short circuit and overload on output L1 - L4
▪
Expandable up to 1000 microphone units
Power supply
▪
Mains voltage: (90 ... 250) VAC, (50 ... 60) Hz
▪
Power consumption: 480 W max.
Housing:
▪
19'', 2 HU, aluminum, silver anodized
▪
WxHxD: 433 x 88 x 330 mm or 17.0 x 3.5 x 13.0 inches (without mounting bracket)
▪
Operating temperature: 0°C to +50°C
▪
Weight: 4.5 kg