WARNING!  Follow instructions of the preservative manufacturer for the proper use of water preservative.

Inspect eyewash unit

1.  Visually inspect the pressure gauge weekly to ensure the unit is maintaining the proper pressure. If the unit is not working 

properly, remove it from the hazard area immediately and refer to the troubleshooting instructions. For further assistance, 
contact the Bradley Corporation.

Clean eyewash unit 

When using potable water only:

1.  Empty the tank any time from once per week to once per month, depending on the quality of your water supply. The 

manufacturer is not responsible for variations in the water supply.

2.  Clean the inside of the tank using warm water and mild soap. Rinse the tank thoroughly with warm water. 

3.  Refill the eyewash tank with tepid potable water.

When using potable water and water preservative (recommended):

1.  Clean the inside of the tank using warm water and mild soap. Rinse the tank thoroughly with warm water. 

2.  Refill the eyewash tank with tepid potable water. Follow instructions of the preservative manufacturer for the proper use of 

water preservative.

Troubleshooting

1.  If pressure relief valve relieves prior to the required pressure, do the following (when in the unpressurized condition):

s

Tighten the valve completely into the cap by turning the gray hex head portion of the pressure relief valve clockwise. 
Do not use a wrench.

s

ull up on the relief valve ring and ensure that the ring is not preventing the valve from closing completely. Push on the 
center pin of the relief valve to ensure that it is completely closed. Repressurize tank to required pressure. This may 
have to be done several times to get the valve to seat completely.

2.  If the pressurized tank loses pressure over time, check the connections with diluted liquid dish soap or children’s bubbles to 

identify the leak location. Tighten the connection slightly and test again.

Summary of Contents for S19-690

Page 1: ...oting 5 S19 690 Components Parts List 6 S19 690LHS Components Parts List 7 Table des mati res Avant l installation 8 Dimensions 9 Installation de la douche oculaire 9 Remplissage du r servoir 10 Entre...

Page 2: ...ay also be found under Products on our web site at www bradleycorp com This unit is to be used with tepid potable water as defined by ANSI Z358 1 Note avoid prolonged exposure to ambient heat sources...

Page 3: ...at this time Attach the eyewash yoke assembly to the tank Max torque 150 In Lbs A Attach the pressure gauge to the adapter on the pressure side of the tank with pipe sealant by installer C NOTICE Whe...

Page 4: ...uld be flushed out per the procedure below Prior to placing unit in service let unit stand for one hour If there is a noticeable pressure drop re pressurize and let stand for an additional hour If uni...

Page 5: ...sing potable water and water preservative recommended 1 Clean the inside of the tank using warm water and mild soap Rinse the tank thoroughly with warm water 2 Refill the eyewash tank with tepid potab...

Page 6: ...1 1 2 1 1 3 1 5 1 3 1 4 1 22 1 2 1 21 2 2 2 3 2 4 2 5 2 6 S45 2410 includes Items 1 21 1 3 Item Part No Qty Description 1 S39 785 1 Tank 10 Gallon 1 1 204 641 1 Operating Instr Label English 204 641FC...

Page 7: ...ch 204 641M 1 Operating Instr Label Spanish 1 2 S44 024 1 Lid Assembly 1 21 269 1410 1 Gasket 1 22 269 1642 1 Relief Valve 1 3 269 1411 2 O Ring 1 4 269 1516 1 Draw Tube 1 5 269 1515 1 Level Indicator...

Page 8: ...us la rubrique Informations techniques sur notre site Internet www bradleycorp com Cet appareil doit tre utilis avec de l eau potable ti de telle que d finie par la norme ANSI Z358 1 Remarque viter l...

Page 9: ...adaptateur avec un enduit d tanch it pour tuyau fournir c t pression du r servoir C AVIS Lors de la pose le manom tre et de la douchette maintenir la adaptateur pi ce 3 avec une cl pour viter d arrach...

Page 10: ...me doit tre purg comme indiqu ci dessous Avant de mettre l appareil en service le laisser au repos pendant une heure S il se produit une chute de pression notable le remettre sous pression et attendr...

Page 11: ...and s 1 Nettoyez l int rieur du r servoir en utilisant l eau chaude et un produit doux de savon Rincez le r servoir compl tement avec de l eau chaud 2 Refaire le plein du r servoir de douche oculaire...

Page 12: ...7 http www bradleycorp com 114 051 1 1 2 1 1 3 1 5 1 3 1 4 1 22 1 2 1 21 2 2 2 3 2 4 2 5 2 6 Pi ce R f Qt Description 1 S39 785 1 R servoir 10 gallons 1 1 204 641 1 tiquette d utilisation anglais 204...

Page 13: ...ation fran ais 204 641M 1 tiquette d utilisation espagnol 1 2 S44 024 1 Couverture 1 21 269 1410 1 Joint 1 22 269 1642 1 Soupape de s curit 1 3 269 1411 2 Bague 1 4 269 1516 1 Tube d aspiration 1 5 26...

Reviews: