Installation
LC800
Bradley Corporation
• 215-947 Rev. H; EN 07-1004C
10/24/08
5
5
Countertop
6
Faucet, Optional Foot Valve and Supplies
Position the countertop inserts over
the brackets on the cabinet and set
the countertop in place. Secure the
countertop to the cabinet with (3)
screws and washers provided.
A
Before connecting supplies, install the
faucet per manufacturer's instructions.
Connect one end of the
supply hose to the supply
shank on the faucet.
Connect the other end of the
hose to the foot valve outlet
connection.
A
Connect the hot and cold
water supply piping to the
1/2" NPT inlet connections
on the foot valve.
B
Connect the P-trap to the sink’s
1-1/4" or 1-1/2" O.D. drain pipe
and to the 1-1/2" O.D. tailpiece
from the wall.
IMPORTANT: Laminate top
option requires 1-1/4" to 1-1/2"
adapter for drain connection.
C
Optional
roll-away
shown
Terreon® top is shown.
Turn on the water supplies and check for leaks and adequate
water fl ow. Activate the faucet, bedpan washer and fl ush valve
seeral times to purge air from the supply lines.
D