LC800
Installation
2
10/24/08
Bradley
Corporation
• 215-947 Rev. H; EN 07-1004C
Supplies Required:
•
(6) 3/8" wall anchors and bolts and washers to secure the cabinet to the wall (minimum pull-out rating of 1,000 lbs.)
•
Steel angles and hardware for anchoring the water closet (if concrete is lightweight or less than 4" thick)
•
Hardware for waste outlet connections
•
Shims (for water closet or cabinet installation, if necessary)
•
Water supply piping to water closet, faucet or foot valve, and optional backflow preventer and bedpan washer
•
Waste outlet piping to water closet
•
P-trap and drain piping
•
5/16" toilet-mounting hardware (for floor-mount option)
IMPORTANT!
BEFORE beginning installation, all supply, drain and waste piping rough-ins
BEFORE beginning installation, all supply, drain and waste piping rough-ins
must be completed according to rough-ins received prior to receiving the unit. If
must be completed according to rough-ins received prior to receiving the unit. If
you have not received rough-ins, contact your Bradley representative.
you have not received rough-ins, contact your Bradley representative.
Read this entire installation manual to ensure proper installation. When fi nished
with the installation, fi le this manual with the owner or maintenance department.
Compliance and conformity to local codes and ordinances is the responsibility
of the installer. Bradley cannot assume any responsibility for personal injury or
damage to equipment due to an improperly installed LC800 unit.
Left-hand model is shown throughout this manual. Installation of right-hand
model is opposite. This manual covers all models included in the Bradley LC800
series. Simply omit the steps that do not apply to the model you are installing.
For units with a laminate top, remove the top before beginning installation.
Separate parts from packaging and make sure all parts are accounted for
before discarding any packaging material. If any parts are missing, do not begin
installation until you obtain the missing parts.
Make sure that all water supply lines have been fl ushed and then completely
turned off before beginning installation. Debris in supply lines can cause valves
to malfunction.
Hardware supplied by installer must be appropriate for wall construction. Wall
anchors used must have a minimum pull-out rating of 1,000 lbs.
Product warranties and service parts information may be found on our web site
at bradleycorp.com.
Installation
TH
IS
SID
E
UP
Packing List
•
•
•
•