Installation
LC800
Bradley Corporation
• 215-947 Rev. H; EN 07-1004C
10/24/08
3
With assistance, lift the cabinet over
the water closet. Secure the cabinet
to the back wall in (6) places with
3/8" anchors and fasteners.
For units with optional china water closet,
refer to manufacturer's instructions.
1a
Floor-Mount Water Closet
2
LC800 Cabinet
A
Align water closet waste outlet per rough-in
submittal. Using the water closet as a template,
drill two 2-1/8" deep holes into the water closet
support anchoring locations (use a 5/8" concrete
drill bit). Holes must be clean and free of debris.
A
Place the water closet over the threaded studs. Connect the water closet
to the floor or wall waste outlet using a flanged gasket connection.
Secure the 1/2" water closet nuts using the nut driver provided. NOTE:
5/16" Acorn nuts also provided for anchoring flange. Additional mounting
hardware supplied by installer.
C
Remove the water closet. Drive the two
2-1/8" anchors provided into the drilled
holes for the water closet using a hammer
and the setting tool supplied. The anchor
should be driven in flush with the floor.
Install the 1/2" x 2" studs provided into the
two 2-1/8" anchors.
IMPORTANT: If the fl oor concrete is
lightweight or less than 4" thick, Bradley
recommends through-bolting to the steel
angles under the fl oor.
B
For cabinets with laminate countertop
option, remove the top prior to installation.
• In-wall carrier is recommended
• Reference submittal for bolt hole pattern
• Mounting hardware supplied by installer
1b
Wall-Mount Water Closet