FL-3H, FL-3L
Installation
8
2/15/2012
Bradley Corporation
• 215-1513 Rev. H; ECM 11-08-011
2
Lavatory Deck
Metal Studs
Drywall
Securely fasten the
plywood to at least (7)
metal studs (plywood
to equal thickness of
drywall, ½" minimum)
Use
³⁄₈
" toggle bolts and
washers to secure the
support brackets to the
plywood (4) places.
16"
(406mm)
96"
(2438mm)
12"
(305mm)
25"
(635mm)
Backing Information
Refer to the rough-ins to determine wall mounting location for optional
mixing valve.
Installer may prefer to install the faucet before mounting the fixture to
the wall. Refer to page 8 for faucet installation details.
If necessary, adjust the fixture height before securing to the support
brackets.