1 of 8
1/29/2018
Bradley
• 215-1833-4 Rev. A: ECN 17-00-021A
Bowl and Pedestal Assembly (Stainless Steel & Terrazzo)
WF2605, WF2608, WF2705, WF2708
P.O. Box 309
•
Menomonee Falls, WI 53052-0309
•
1 800 BRADLEY
•
262 251 6000
•
bradleycorp.com
This document describes installation of washfountain bowl and pedestal only. Some optional equipment and
accessories are shown for clarity. For activation, optional equipment and accessory installation, see installation
documents included with those parts.
Supplies Required by Installer
• (8) 1/2" lag bolts, screws or other fasteners to anchor washfountain pedestal to floor
• 1" hot and cold water supply lines and fittings (see activation instructions)
• Reducing fittings and 1/2" nom. copper tubing supply lines for types with supplies from above (see
activation instructions)
• Standard 2" P-trap (vented trap supplied by Bradley when required)
• 2" drain lines and fittings (see activation instructions)
• 1-1/2" vent pipe on types vented through washfountain column
• Pipe sealant and plumber's putty
Before installation of bowl and pedestal assemblies, review all included instructions. Some options may require
additional steps during the bowl and pedestal installation process.
Supply lines for one or two washfountains should be 1"; for three washfountains 1-1/4"; for more than three
washfountains, pipe size should increase proportionally. Vent pipe to be 1-1/2" on models vented through
washfountain.
Valving installations for Classic washfountains require rigid plumbing installation and connections to ensure
proper operation and support of the valve assemblies, especially for foot control activated washfountains. Do
not use flexible supply hoses unless specified in your activation instruction documentation and supplied with
your washfountain.