7910 Single Valve Recessed Hose Box
Installation
2
1/26/2011
Bradley
Corporation
• 215-1699 Rev. B; EN 10-07-009
Supplies Required:
•
Hardware for anchoring the Hose Box to framing or wall studs
•
1/2" NPT supply connection
•
For optional left side supply: Teflon plumber's tape or Perma-Lok (or equivalent)
Tools Required:
•
Security Allen Wrench (provided)
•
Flat head Screwdriver
•
Small crescent wrench
Rough-In Dimensions
8-5/8" (219) x 8-5/8" (219) wall opening
Top View
Front View
Side View
8-5/8"
(219)
8-5/8"
(219)
12-5/8"
(321)
10"
(254)
10"
(254)
5-7/8"
(147)
1"
(25)
4"
(102)
1-7/8"
(48)
(mm)
Security
Allen Wrench
(provided)
1
Mount Box in Wall
A
Remove door assembly
prior to mounting.
B
Mount box so front edge will be
fl ush with FINISHED wall.
Rough in support frame and mount
box before attaching drywall or other
wall coverings.
Unit is fully assembled at factory for right side supply. For left side supply option,
refer to instructions on page 3 before mounting unit in wall.