background image

Installation

 

7910 Single Valve Recessed Hose Box

Bradley Corporation

 • 215-1699 Rev. B; EN  10-07-009 

1/26/2011 

3

2

Connect Supply

Optional Left Supply Confi guration

A

Connect 1/2

"

 NPT supply. 

(Side connection shown.)

C

Activate supply and test for leaks. 
Adjust stop point if necessary. 
Re-attach door.

B

Tighten vacuum breaker onto hose 
bibb and secure by tightening screw.

A

Remove door. After carefully noting 
configuration of fittings, remove 
vacuum breaker from hose bibb. 

B

Remove stand-off bracket, hose bibb and other 
components from inner box. Disassemble fittings.

C

Rotate cabinet 180

˚ 

so outlet holes are on the left.

 

Re-install 

valve and stand-off bracket, being careful to align screwdriver 
stop with stop hole in cabinet. Proceed to Step 1 on page 2.

Left supply confi guration is the opposite of standard right supply confi guration. 

Thoroughly clean threads and seal with plumber's 
tape or Perma-Lok (or equivalent). 

Vacuum breaker's break-away screw (or 
set screw) is not tightened at factory. 

Stand-Off 

Bracket

Hose Bibb

Vacuum 

Breaker

Screwdriver 

Stop

Screwdriver 

Stop Hole

Outlet 

Holes

Elbow (remove for top 

connection)

Reviews: