3
Installation
Bradley TouchTime
™
Individual Built-In Wall Shower with Concealed Supplies
Bradley •
215-1152 Rev. E; ECN 13-03-022
1/9/2014
Make electrical connections
Complete Installation
1
2
A
B
A
B
C
D
Install a 24 VAC Class II transformer in a
remote location a safe distance from the
shower room . Connect the wire designated
24 VAC to the wire on the transformer .
NOTE: The connectors will only fit into the
transformer wire.
Connect the wire designated SOL-1 to the solenoid valve connectors .
NOTE: The wires can be connected to the solenoid in any order.
Secure the showerhead to the 1/4"-20 wall
anchors (supplied by installer) using the
screws provided .
Secure the pushbutton to the #10 wall
anchors (supplied by installer) .
Turn on the water supply to your 1C TT
shower and check for leaking .
Turn on the 24 VAC power to the shower
and press the pushbutton several times to
purge air from the lines .
NOTE: Refer to figure below when making electrical connections
IMPORTANT: DO NOT put the 24 VAC Class II transformer in the shower room. Check local codes and
ordinances for proper location and connection requirements. Conformity to local codes is the
responsibility of the installer.
IMPORTANT: DO NOT turn 24 VAC power on to your shower until installation is complete.
IMPORTANT: Verify that the electrical source to the fixture is 24 VAC.
IMPORTANT: Connection of leads other than shown in figure below may cause permanent damage to
the electrodes.
Solenoid Valve
(the wires can be connected to the
solenoid valve in any order
110/24 VAC
Transformer
(Optional)
Pushbutton
Assembly
Connect either
black or brown
wire to either
terminal
Plug-in
Transformer
(Optional)
SOL-1
wires
24 VAC