Installation 

Bradley TouchTime

 Individual Built-In Wall Shower with Concealed Supplies

Bradley • 

215-1152 Rev. E; ECN 13-03-022 

1/9/2014

Make electrical connections

Complete Installation

1

2

A

B

A

B

C

D

Install a 24 VAC Class II transformer in a 
remote location a safe distance from the 
shower room . Connect the wire designated 
24 VAC to the wire on the transformer .

NOTE: The connectors will only fit into the 

transformer wire.

Connect the wire designated SOL-1 to the solenoid valve connectors .

NOTE: The wires can be connected to the solenoid in any order.

Secure the showerhead to the 1/4"-20 wall 
anchors (supplied by installer) using the 
screws provided .

Secure the pushbutton to the #10 wall 
anchors (supplied by installer) .

Turn on the water supply to your 1C TT 
shower and check for leaking .

Turn on the 24 VAC power to the shower 
and press the pushbutton several times to 
purge air from the lines .

NOTE: Refer to figure below when making electrical connections

IMPORTANT:  DO NOT put the 24 VAC Class II transformer in the shower room. Check local codes and 

ordinances for proper location and connection requirements. Conformity to local codes is the 
responsibility of the installer.

IMPORTANT:  DO NOT turn 24 VAC power on to your shower until installation is complete.

IMPORTANT:  Verify that the electrical source to the fixture is 24 VAC.

IMPORTANT:  Connection of leads other than shown in figure below may cause permanent damage to 

the electrodes.

Solenoid Valve 

(the wires can be connected to the 

solenoid valve in any order

110/24 VAC 

Transformer 

(Optional)

Pushbutton 

Assembly

Connect either 

black or brown 

wire to either 

terminal

Plug-in 

Transformer 

(Optional)

SOL-1 

wires

24 VAC