Maintenance and service
RTG 199 ME – 6 720 811 615 (2015/04)
40
7.5
Program values
This section describes details on programming the appliance. For most
applications the factory default values will provide robust and stable
operation. Only adjust the factory settings if the installation requires
changes as indicated in the appropriate section of this manual.
Refer to chapter 7.6 Control board diagnostics (page 41) regarding how
to access these P-modes.
CAUTION:
Appliance malfunction!
▶ Misadjusted program values can lead to appliance
malfunction, errors, and service calls.
Program
Description
Factory Default
MIN
MAX
Comment
P1
Maximum Power
NG: 54,
LP: 46
21
NG: 55,
LP: 49
note: reducing P1 values below maximum will
reduce maximum power of the appliance.
P2
Minimum Power
7
7
20
P3
Remote
Controls installed
_0
_0
6
Not available
P4
Access to
Diagnostic Mode
E
0d
10f
P5
Cascade Mode
NO
NO
CC
contact manufacturer for details
P6
Temperature Unit
°F
°F
°C
P7
Gas type selection
LP or NG
Preset from factory.
Contact manufacturer for details.
P8
Back light
dE
dE
On
dE turns back light off after 60 seconds from
last button pushed, ON turns backlight on
permanently.
P9
Fan Purge
Runs secondary fan and primary fan when P9
is selected by depressing the “P” - button
PH
Cascading type
IC
IC
SC
This menu is only available when cascade
mode is selected CC.
Contact manufacturer for details.
PC
Primary/Secondary
mode
CS
CS
Cn
Table 37 Program values, factory default settings and ranges.