p.
29
-
Ins
ta
lla
tio
n
M
anu
al
c
od
e
24
805
67
0/
06
-05
-2
01
3 3
19
F8
0C
- v
er
1.
0
- T
he d
at
a a
nd i
nf
or
m
at
io
n i
n t
hi
s m
an
ua
l m
ay b
e c
ha
ng
ed a
t a
ny t
im
e w
ith n
o o
bl
ig
at
io
n o
n B
ra
hm
s’
s p
ar
t t
o n
ot
ify a
ny
on
e o
f t
hi
s.
ENGLISH
• Cabling outputs.
• Cabling the control unit.
• Cabling keypads, inserters, accessories, …
Below is an explanation of how to start up the system.
10.1 First start up
Check connections to ground and 230 Vac main power supply.
PRELIMINARY CHECKS
SYSTEM UNDERGOING MAINTENANCE / OPERATIONAL
To prevent accidental calls or sirens up when system undergoes maintenace jobs, setting the system to MAINTENANCE mode will
disable said warning functions.
The deactivated control unit under maintenance:
• Telephone calls and SMS text messages.
• Activating the alarm outputs.
The User Menu can be used to test any disabled functions.
To change maintenance / operational, operate on switch [SW1.1]
in maintenace
operational
O
N
1
O
N
1
Visualising the state of maintenance can only be done on LCD keypads.
SYSTEM IN MAINTENANCE
SYSTEM UP AND OPERATIONAL
First line of the display reading
“in maintenance” message
First line of the display with
time and date of the control unit
IN MAINTENACE
ENTER CODE
08:23 16/05/10
ENTER CODE
CONTROL UNIT POWER ON
• Power up the control unit with 230 Vac and connected the battery.
• When first switched on the control unit follows the configuration of the
POWER ON CENTRALE
parameter which is normally
set to
TOTAL ON
.
• Switch off the system by keying in user code
123456
followed by the switching off button
D
.
OPENING/CLOSING THE CONTROL UNIT
If the control unit tamper is properly installed, when the control unit door is opened the sabotage- allarm will sound immediately.
For alarm not to sound, access technical menu via keypad.
STEP 1: Opening the control unit
1.
Enter user code (if less than 6 characters confirm with
*
).
2.
Enter technical code to access technical menu.
3.
Open the control unit by loosening the apposite screws.
STEP 2: Placing the control unit in maintenance
To prevent alarms from being raised due to control unit tamper or due to possible pro-
gramming errors, we suggest placing the control unit into maintenance mode.
1.
Place the control unit into maintenance mode
O
N
1
by raising microswitch 1.
08:23 16/05/10
ENTER CODE
123456
COMMAND WAITIG
*=USER MENU
222222
CHANGE CONTROL UNIT LANGUAGE
The control unit can support the management of multiple languages through the PXLNG interface which allows installation of the desired language.
To change the language, please refer to the manual included with the PXLNG board.
Updating the language makes it possible to update the firmware as well.