STEP 1: Addressing the expansion
1.
On the address you wish to assign set the expansion by acting on the
4 microswitches (Example address 1:
O
N
1
).
2.
Cut off and then restore power supply to the module.
STEP 2: Activating input expansion on bus
1.
Enter user code (if less than 6 characters confirm with
*
).
2.
Enter technical code to access technical menu.
3.
With
▲
▼
select
SYSTEM
and press
*
.
4.
With
▲
▼
select
EDIT SYSTEM
and press
*
.
5.
With
▲
▼
select
OUTPUTS MODULE
.
6.
Press the number key for the expansion address which you need to
activate by adding
#
(# = activated. - deactivated).
7. Press
#
to output and return to the previous menus.
8.
The communication LED light on the module bus starts flashing.
08:23 16/05/10
ENTER CODE
123456
COMMAND WAITING
*=USER MENU
222222
SYSTEM 02
EDIT
SYSTEM
*
▼ ▲
▼ ▲
OUTPUTS MODULES
------------------
▼ ▲
*
OUTPUTS MODULES
#-----------------
#
1
ACQUIRING OUTPUT EXPANSION MODULES ON BUS
The system cannot have output expansion modules on bus with the same address.
All expansions are made with address 1 and the control units have no factory-activated expansion.
To set up control unit for expansion, you need to: