ENGLISH
5.4 Wall mounting
Proxinet 36 - Proxinet 76 - Proxinet 192
Install the control unit far from access points and so it is hard to find.
Secure onto a suitable wall that can permanently hold up the control unit.
Set it up to have holes and channels for the initial installation cables to pass through.
Use the specific four holes for securing to the wall.
5.5 Cabling
Proxinet 36
Proxinet 76
Proxinet 192
– Cut off the magnetothermic switch linked to the control unit before the network 230 Vac and for the entire time the
control unit is open.
– Handling the 230 Vac main power supply cables is hazardous; risk of electrecution.
– Connect the ground via a Faston to the appposite connector (Proxinet 36, Proxinet 76), or to the PE terminal (Proxinet
192). Connecting the ground must be done in compliance with current regulations.
– Connect the Line cable and the Neutral of thr 230 Vac to the transformer terminals.
– Block the 230 Vac power supply cable in the container so that it cannot move even if the terminals are disconneted.
– Before closing the control unit check that all of the metal parts are connected to the ground (control unit and cover).
– Re-attach the magnetothermic switch associated with the control unit only once internal cabling of the control unit.
230 Vac
Set up a suitable bipolar cut-off device (magnetothermic switch), with distances greater than 3 mm between contacts, wit
sectioned power source.