DESCRIPTION
GENERAL WARNINGS
Technical data
Type
VA/01
Power supply (V AC)
230
Max current draw at (mA AC)
350
Max dissipated power (W)
25
Rated power supply for entry panels (V DC)
18
Current draw for entry panels (mA)
600
Peak power supply for entry panels (V DC)
18
Peak current draw for entry panels (A)
1.1 *
Power supply for riser (V)
20
Type
VA/01
Current draw for riser, for 1’ (mA)
800
Current draw for riser, for 3’ (mA)
200
DIN modules EN 50022 35x7.5 (n°)
12
Storage temperature (°C)
-25 to +70
Operating temperature (°C)
0 to +35
Protection rating (IP)
30
(*) 1.6 A if the riser is not connected or is powered separately.
• Read the instructions carefully before starting installation and proceed as
specified by the manufacturer.
• Installation, programming, commissioning and maintenance of the product
must only be performed by qualified technicians who have been properly trai-
ned in compliance with current standards, including health and safety and
packaging disposal regulations.
• Control boards can be seriously damaged by electrostatic discharges: if
you need to handle them, wear suitable antistatic clothing and footwear or at
least make sure you have removed any residual charge beforehand by tapping
your fingertips on a metal surface connected to the earthing system (e.g. the
chassis of a household appliance).
• Before performing any cleaning or maintenance operation, disconnect the
power supply to the device.
• The device must only be used for the purpose for which it was explicitly
designed.
• The manufacturer declines all liability for any damage as a result of impro-
per, incorrect or unreasonable use.
The data and information provided in this manual are subject to change at any
time without prior notice.
Measurements, unless otherwise indicated, are in millimetres.
Video entry system power supply for X1 systems.