18
Cleaning, maintenance and repair
Sprühboy 04s - Airless Edition 10.12
5.1
Cleaning intervals
Clean the agent hose with the spray gun daily. Use
the cleaning adapter WRA for this purpose (1).
5.2
Cleaning
There are two different kinds of cleaning
processes:
•
cleaning the spray gun and agent
hose at the end of every production
run, e.g. if the filled stainless steel
pressure vessel is stored in cold
storage and
•
cleaning the entire implement.
Always clean the spray gun and the
agent hose at the end of every
production run with hot rinsing water
and a disinfecting, grease solving
cleaning agent.
Rinse
the
implement
for
hygienic
reasons with hot rinsing water regularly.
Also carry out this cleaning process with
disinfecting cleaning agents. Rinse the
implement very thoroughly with clear
water after every use of disinfecting
cleaning agents. Completely spray out
any water residues. Use compressed air
to blow dry the individual components.
The vessel must be absolutely dry
before it is filled again. If even a single
drop of water gets into the system, this
water drop could get lodged in front of
the agent nozzle and prevent agent
discharging from the nozzle.