Routine Service and Maintenance
4.21
Do not over fill the hydraulic system. Damage to the hydraulic system might result.
e.
Unscrew the dipstick assembly and remove from the machine and fill the hydraulic tank
with the proper hydraulic fluid (Chevron Rykon Premium ISO 46 or equivalent) until
the fluid level is at but not above the upper marker hole in the dipstick.
Figure 4-22 Hydraulic Fluid Level Dip Stick
f. Start the machine and run the engine at low idle for several minutes. Shut off the engine.
g.
Recheck the hydraulic fluid level as described above.
NOTICE