Routine Service and Maintenance
4.18
e. Loosen, but DO NOT remove, the air bleed bolt (Item 2,
Figure 4–19
).
f. Raise and lower the primer pump handle (Item 1,
Figure 4–19
) until only diesel fuel
without any air bubbles comes out of the air bleed.
g. Fully tighten the air bleed bolt.
Figure 4-19 Fuel Feed Pump Lever
6. Check battery for signs of leakage and for corrosion on the battery cables.
• On a monthly basis, check the battery for signs of leaking electrolyte. If any signs of
damage are visible, remove and replace the battery.
Wear the proper protective clothing when handling the battery. Leaking battery fluid
contains acid that can cause burns. Fumes from the leaking fluid can cause respiratory
problems.
• To prevent corrosion, spray on a battery protectent and sealer onto both terminals and
cable clamps after cables are installed.
• The electrical system on this machine is a NEGATIVE ground system.
• Check both of the battery cables for signs of damage or corrosion. Loosen the cable
clamps and remove the cable from the battery. Clean the terminals with a battery brush.
Reinstall and secure the cable clamps.
CAUTION
Summary of Contents for 700HDX
Page 3: ...III...
Page 6: ...VI Morbark LLC 8507 South Winn Road P O Box 1000 Winn MI 48896 Affix Stamp Here...
Page 18: ...Safety Precautions 1 8...
Page 21: ...Operating Controls 2 3 Safety Decals...
Page 26: ...Operating Controls 2 8...
Page 33: ...Pre Start Inspection and Operation 3 7 Figure 3 7 Lubrication Points CAUTION...
Page 52: ...Pre Start Inspection and Operation 3 26...
Page 65: ...Routine Service and Maintenance 4 12 Figure 4 12 Track Extension Widening Stop Bolt 1 2 3...
Page 87: ...Troubleshooting 5 4...
Page 91: ...General Specifications 6 4...