8. Attach the power cord and turn on the Treadmill by flipping the power switch to ON.
9. From the Power Up (or Welcome) screen, push and hold down the PAUSE/STOP button and Down arrow button for about 5 seconds to go into the
Machine Setting Mode. The Console display will show the TOTAL HOURS screen.
10. Push and hold down the PAUSE/STOP button and Down arrow button for about 5 seconds to go into the Engineering Mode.
11. Push the Down arrow button 12 times until the Console displays “ENTR MCB CLB”.
Be sure the area around the Treadmill is clear of all bystanders, children and pets. Be sure there is nothing on or under the Walking
Belt, or near the Treadmill.
12. The Console will display “MCB CALIB”.
13. With the area clear, push the ENTER button. The calibration procedure will begin by automatically moving the Walking Belt.
Be sure not to touch or allow anyone else to touch the machine while calibration is occurring.
14. When calibration is complete, the Console will display “DONE”.
15. Push the PAUSE/STOP button to exit the Engineering Mode.
16. Flip the power switch to OFF. Calibration is now complete for the machine.
17. Final Inspection
Inspect your machine to ensure that all hardware is tight and components are properly assembled.
Do not use until the machine has been fully assembled and inspected for correct performance in accordance with the Owner’s
Manual.