SMARTWALL HORIZONTAL

TECHNICAL DRAWINGS

Telephone: 0800 003 006

Terranota Ltd. P.O. Box 1703 Invercargill 1703

Email: [email protected]
Website: www.boundaryline.co.nz

MODEL

SMARTWALL 1800

HORIZONTAL

Issue Date

23-04-2019

scale

1:16

Unless Otherwise specified

All units in Millimeters
Linear Tol/- 0.5mm overall
Angular Tol/- 0.5mm overall

Revision

Patent Pending NZ Pat. App. 745289/753226

'GOOD GROUND' 100KPA

ALLOWABLE BEARING AS

DEFINED BY NZS

 3604

SLOPE TOP OF
CONCRETE TO ALLOW
WATER TO DRAIN
AWAY FROM POST

CONCRETE 17.5MPA MIN

250.0mm

1830.0

A

B

A

A

B

B

10:1

A

10:1

B

VERTICAL BEAD

POST

POST CAPS

CLT LAMINATED PALING

SCREW

POST CAP

TOP RAIL

POST

CLT LAMINATED PALING

VERTICAL BEAD

100.0

275.0

15.0

28.0

A-A

B-B

TOP RAIL

1800.0

2400.0

Summary of Contents for SMARTWALL

Page 1: ...STEP BY STEP GUIDE INSTALL GUIDE SMARTWALL A STEP BY STEP GUIDE TO INSTALLING YOUR FENCE...

Page 2: ...ART READTHIS TOOLS LIST It is recommended that the reader pays particular attention to those items identified as IMPORTANT in this manual to ensure satisfactory long term performance IMPORTANT the tab...

Page 3: ...STALLING POSTS a Fastening posts together b Fixing post in ground If it isn t possible to fix posts as proposed here please contact us for further information IMPORTANT Approx 40mm 2 Fasteners approx...

Page 4: ...l A rubber mallet can be used if required Continue to insert all palings ensuring the tongue and groove joint is in place correctly Once all palings are installed it is time to fit your top rail Slide...

Page 5: ...ay particular attention to the area under the top rail which is sheltered from natural washing by rain 2 DO NOT build up soil garden fill and or dirt against the bottom rails and posts of your fence a...

Page 6: ...ess Otherwise specified All units in Millimeters Linear Tolerance 0 5mm overall Angular Tolerance 0 5mm overall Revision Patent Pending NZ Pat App 745289 753226 POST CAP POST TOP RAIL CLT LAMINATED PA...

Page 7: ...rwise specified All units in Millimeters Linear Tolerance 0 5mm overall Angular Tolerance 0 5mm overall Revision Patent Pending NZ Pat App 745289 753226 GOOD GROUND 100KPA ALLOWABLE BEARING AS DEFINED...

Page 8: ...s including the number of surrounding properties and how exposed the location is If your property is exposed to higher wind speeds please contact us for further advice recommendations Also if in proxi...

Reviews: