completely, but the vacated hole must be blanked off.
Page 26
Section 5 - Flues
5:1 POSITIONING THE BOILER
Read Sections 5:2 & 5:3
Some combustion noise occurs at the Exhaust Terminal of Balanced Flues and care should be exercised to
ensure that the position of the exhaust is not near doors or opening windows of the house it serves, or doors
or windows of any neighbouring house.
Fig 5.1
Table to above Flue Terminal Positions - MINIMUM dimensions
REF
DESCRIPTION
DISTANCE IN MM
A
Directly below an Opening, Air Brick or Window
600
B
Below a Gutter, Sanitary Pipework or Eaves
75 (600')
C
From any Internal Corner
300 (900)
E
From a surface facing the Terminal
600 (1200)
F
From a Terminal facing a Terminal
1200
J
From any External Corner
300 (600)
Page 37 of 57
Installation & maintenance manual for Camray 5 Combi External Boilers
14/04/2005