3:7 COMMISSIONING DATA
3:7.1 Class C2 Kerosene Oil
3:8 PERFORMANCE DATA
Dynamic Inlet pressures
/
flow rates
Model
Output
Riello R00
type
Nozzle
Danfoss
Delevan
US/GPH
Pump
pressure
fuel rate
Kg/h
C02%
Smoke
no.
Flue
exit
temp. °
C
kW
Btu/hx1000
bar
psi
90A
26.4
90
483T50
0,85x60°W
8.0
115
2.57
12
0-1
204
Page 16 of 57