INSTALLATION
VERTICAL, 90 DEGREE ELBOW TO HORIZONTAL OUT THE
WALL (12-in minimum rise before elbow)
90° ELBOW
“A” PIPE
LENGTH
FIRESTOP SPACER
(INCLUDED)
VENT CAP
WALL FIRESTOP/
THIMBLE
B
C
A
B
C
6-in
14-in
7in Maximum
9-in
15-1/2-in - 18-in
8-1/2-in - 11-in
12-in
18-in - 20-1/2-in
11-in - 13-1/2-in
Figure 34
CORNER INSTALLATION - VERTICAL, 90 DEGREE ELBOW
TO HORIZONTAL OUT THE WALL
(12-in minimum rise before elbow)
NOTE: DIMENSIONS SHOWN WITH FRAMING
SET ½” BEHIND THE FIREPLACE FACE
A
D
B
C
Model
A
B
C
D
DVLL48BP 101-5/8-in
51
71-7/8-in
23
DVLL60BP 113-5/8-in
57
80-1/2-in
31-5/8-in
Figure 35
Note:
Corner installation will require more vertical vent pipe
than just the minimum required depending on wall thickness and
horizontal dimension. Refer to Figure 44, page 27.