4-3
Chapter 4 • Electrical
R
325 Conquest
13
1
2
4
5
GYRO* (OPTION) BATTERY COMPARTMENT
GYRO* REMOTE BATTERY SWITCH
GYRO* 100 AMP BREAKER
GYRO* BATT CHARGER REMOTE DISPLAY
GYRO* BATTERY
*Gyroscopic stabilizer
1
2
3
4
5
Remote Battery Switch Locations
(Figure 4.3.1)
The bow thruster battery
switch has two settings:
OFF
- No power to bow
thruster.
ON
- Power to bow
thruster
Bow Thruster Switch
This vessel uses a battery
switch for the bow thruster
(if equipped) to control
delivery of DC power from
the batteries.
The battery switch is located
on the port bulkhead inside
the aft bilge compartment.
O
ON
II
OFF
O
ON
II
OFF
O
ON
II
OFF
Batteries are automatically connected in parallel
through the use of automatic charging relays (ACR)
when a sufficient charging source is present. The
battery banks are automatically separated when the
charging source falls below a certain voltage level
for a predetermined amount of time.
The use of automatic charging relays eliminates the
need for the operator to monitor battery voltage and
decide whether or not to parallel the battery banks. It
also eliminates the chance of a dead battery bank if a
paralleling switch were left in the combined position
without a sufficient charging source present. In an
emergency, the operation of the automatic charging
relays can be manually overridden by use of the knob
on the top of the automatic charging relays.
Automatic Charging Relays (ACR)
REFER TO THE OWNER’S PACKET FOR COMPLETE
INSTRUCTIONS AND WARRANTY INFORMATION.
Manual Control Override
Each of the remote battery switches and automatic
charging relays have a manual override knob as
an added level of safety that allows manual on/off
control with or without power and provides lock off
for servicing the electrical system.
Manual Control Override Knob Operation
To combine
battery banks
With Override Knob in
(
REMOTE
position) push
button until latched (push to
latch on
).
To isolate battery
banks that are
connected
1. Rotate Override Knob to
right to release button from
latch on mode (button pops
up). 2. Rotate Override Knob
to left (
REMOTE
position).
To prevent remote
operation.
Rotate Override knob to right
(
LOCK OF
F position).
To secure for
servicing.
With Override knob in (
LOCK
OFF
position), pass cable tie
through hole.
1
2
Summary of Contents for 325 Conquest
Page 1: ......
Page 21: ...285 Conquest 325 Conquest R Introduction THIS PAGE INTENTIONALLY LEFT BLANK Intro 18...
Page 46: ...1 25 Chapter 1 Safety 325 Conquest R THIS PAGE INTENTIONALLY LEFT BLANK...
Page 78: ...2 32 Chapter 2 General Information R 325 Conquest THIS PAGE INTENTIONALLY LEFT BLANK...
Page 131: ...4 18 Chapter 4 Electrical R 325 Conquest...
Page 153: ...4 40 Chapter 4 Electrical R 325 Conquest Main DC Battery RBS DC joystick Figure 4 40 1...
Page 154: ...4 41 Chapter 4 Electrical R 325 Conquest Main DC Battery RBS DC standard Figure 4 41 1...
Page 156: ...4 43 Chapter 4 Electrical R 325 Conquest Bow Thruster DC Figure 4 43 1...
Page 157: ...4 44 Chapter 4 Electrical R 325 Conquest Main DC Figure 4 44 1...
Page 158: ...4 45 Chapter 4 Electrical R 325 Conquest DC Battery Layout Figure 4 45 1...
Page 159: ...4 46 Chapter 4 Electrical R 325 Conquest Headliner DC Figure 4 46 1...
Page 160: ...4 47 Chapter 4 Electrical R 325 Conquest Hardtop DC Figure 4 47 1...
Page 161: ...4 48 Chapter 4 Electrical R 325 Conquest Cabin DC Figure 4 48 1...
Page 163: ...4 50 Chapter 4 Electrical R 325 Conquest Windshield Washer Wiper DC Figure 4 50 1...
Page 170: ...4 57 Chapter 4 Electrical R 325 Conquest Head Switch Panel DC Figure 4 57 1...
Page 171: ...4 58 Chapter 4 Electrical R 325 Conquest Cabin Breaker Panel DC Figure 4 58 1...
Page 173: ...4 60 Chapter 4 Electrical R 325 Conquest Helm Switch Panel DC Figure 4 60 1...
Page 176: ...4 63 Chapter 4 Electrical R 325 Conquest Shore Power with Generator 120V 60Hz AC Figure 4 63 1...
Page 177: ...4 64 Chapter 4 Electrical R 325 Conquest Shore Power no Generator 120V 60Hz AC Figure 4 64 1...
Page 180: ...4 67 Chapter 4 Electrical R 325 Conquest Shore Power 1 AC System 120V 60Hz Figure 4 67 1...
Page 181: ...4 68 Chapter 4 Electrical R 325 Conquest Shore Power 2 AC System 120V 60Hz Figure 4 68 1...
Page 182: ...4 69 Chapter 4 Electrical R 325 Conquest Grill 120VAC and Fridge 12VDC Figure 4 69 1...
Page 185: ...4 72 Chapter 4 Electrical R 325 Conquest Shore Power with Generator 230V 50Hz AC Figure 4 72 1...
Page 186: ...4 73 Chapter 4 Electrical R 325 Conquest Shore Power no Generator 230V 50Hz AC Figure 4 73 1...
Page 189: ...4 76 Chapter 4 Electrical R 325 Conquest Shore Power 1 AC System 230V 50Hz Figure 4 76 1...
Page 190: ...4 77 Chapter 4 Electrical R 325 Conquest Shore Power 2 AC System 230V 50Hz Figure 4 77 1...
Page 191: ...4 78 Chapter 4 Electrical R 325 Conquest Grill 230VAC and Fridge 12VDC Figure 4 78 1...
Page 192: ...4 79 Chapter 4 Electrical R 325 Conquest Generator 120V 60Hz AC Figure 4 79 1...
Page 193: ...4 80 Chapter 4 Electrical R 325 Conquest Generator 230V 50Hz AC Figure 4 80 1...
Page 194: ...4 81 Chapter 4 Electrical R 325 Conquest Gyroscopic Stabilizer 120V 60Hz AC Figure 4 81 1...
Page 195: ...4 82 Chapter 4 Electrical R 325 Conquest Gyroscopic Stabilizer 230V 50Hz AC Figure 4 82 1...