INSTALLING THE METAL CONNECTOR ATTACHMENT TO YOUR BOSTITCH N88RH-2MCN
- Disconnect tool from air supply before attempting any parts disassembly and
before changing the work contacting element.
- Push in on locking button.(See figure 1)
- Slide contact arm down until it easily detaches from the tool.
- Depress Locking Button and fully slide Metal Connector Attachment onto tool as
shown in figure 2.
- Release Locking Button.
- Make sure that Metal Connector attachment is installed in the full up -
position and that the locking button has returned to release position.
NOTE: The Metal Connector Attachment is not adjustable for depth control.
- Check that the Metal Connector Attachment now moves freely up and down. If not,
DO NOT USE
. Have tool and Metal Connector Attachment serviced by an authorized
service center.
- Reverse procedure to remove Metal Connector Attachment and to install
standard framing Lower Contact Arm.
Always check that the Lower Contact Arm or Metal Connector
Attachment moves freely before using tool. If any binding occurs, repeat assembly
procedure or have tool serviced at an authorized Bostitch service center.
For locations call: 1-800-556-6696
If further information is required, call Bostitch Customer Service at 1-800-556-6696 or
write to: Bostitch Customer Service, Briggs Drive, East Greenwich, RI 02818.
BOSTITCH
East Greenwich, Rhode Island 02818 USA
Figure 1