-9-
DIAL-A-DEPTH™ FASTENER CONTROL ADJUSTMENT
The DIAL-A-DEPTH™ Fastener control adjustment feature provides close control
of the fastener drive depth: from flush with the work surface to shallow or deep
countersink.
First set the air pressure for consistent drive in the specific work as described on
page
5
, then use the DIAL-A-DEPTH™ fastener control adjustment to give the
desired depth of drive.
IN ADDITION TO THE OTHER WARNINGS CONTAINED IN THIS
MANUAL OBSERVE THE FOLLOWING FOR SAFE OPERATION
• Use the BOSTITCH pneumatic tool only for the purpose for which it was designed.
• Never use this tool in a manner that could cause a fastener to be directed toward the user
or others in the work area.
• Do not use the tool as a hammer.
• Always carry the tool by the handle. Never carry the tool by the air hose.
• Do not alter or modify this tool from the original design or function without approval from BOSTITCH, INC.
• Always be aware that misuse and improper handling of this tool can cause injury to
yourself and others.
• Never clamp or tape the trigger or contact trip in an actuated position.
• Never leave a tool unattended with the air hose attached.
• Do not operate this tool if it does not contain a legible WARNING LABEL.
• Do not continue to use a tool that leaks air or does not function properly. Notify your nearest
Bostitch representative if your tool continues to experience functional problems.
Dial-A-Depth
TM
Fastener Control Adjustment
16“ O.C. GAUGE
16” O.C. gauge helps to indicate stud location.
1. Pull up the O.C. gauge to rotate to the opposite side.
2. Press on the O.C. gauge to snap into the magazine.
3. 16“ is measured from nose to the tip of O.C. gauge to help find stud.
16“
INTEGRATED AIR BLOWER
NEVER blow debris toward yourself to others in the work area.
N62FNB has a integrated air blower that helps
clean debris while working. Press the integrated
air blower button. Compressed air will be ejected
out from front of the tool. Released the button to
stop blowing air.