PANEL FUNCTION ILLUSTRATION
Front panel instruction
1.
STICK/LIFT TIG/MIG switch key
2.
WIRE Check/Inch
3.
VRD/2T/4Tswitch key
4.
Data selection key (effective under MIG mode)
5.
Multifunctional data adjusting knob (coarse adjustment by pressing the knob and turning it: big
regulation rate and high speed; fine adjustment only by turning the knob: small regulation rate and
low speed)
6.
Multifunctional data display
Polarity conversion joint
•
This machine has the polarity conversion
•
There are positive output terminal and negative output terminal between wire feeder and wire
spool.
•
When use solid wire with gas protection, the torch socket should be connected to the positive
output terminal, ground cable should be connected to the negative output terminal.
•
When use flux-cored wire (Gasless), the torch socket should be connected to the negative output
terminal, ground cable should be connected to the positive output terminal.