5.2 KEY PARAMETERS
THE 6TH CHAPTER APPENDIX
6.1 RESTORE FACTORY DEFAULT SETTINGS
Sometimes factory default setting can be restored by making use of web page, if users
can not enter into web page, the below methods can be followed.
Turn off the power supply, and press the restoration button at the bottom of IP606W, then
connect the power supply again, after a few seconds ,the green LED will flash, factory
default setting of all parameters can be restored.
6.2 TROUBLE SHOOTING
1
、
Can not find the device by making use of the searching program.
Please check if there is a correct physical connection? A-B network cable will be required
if device connects with the PC directly
2
、
Can not open the web page.
The IP addresses of PC and the device are not in the same web space, or different subnet
mask, or the IP addresses of devices are in conflict. The IP address of PC can not be set
up as “automatically obtain IP”.