background image

SAFETY WARNING: Never put your hand into area housing the fan while the fan is operating!

For optimal operation, clean range hood and all baffle/spacer/filter/grease tunnel/oil container regularly. Regular care will 

help preserve the appearance of the range hood.

Cleaning Exterior surfaces:

Clean periodically with hot soapy water and clean cotton cloth. Do not use corrosive or abrasive detergent (e.g. Comet 

• 

Power Scruv

®

, EZ-Off

®

 oven cleaner), or steel wool/scoring pads, which will scratch and damage the stainless steel 

surface. For heavier soil use liquid degrease such as “Forumla 409

®

” or “Fantastic

®

” brand cleaner.

If hood looks splotchy (stainless steel hood), use a stainless steel cleaner to clean the surface of the hood. Avoid getting 

• 

cleaning solution onto or into the control panel. Follow directions of the stainless steel cleaner. 

CAUTION: Do not 

leave on too long as this may cause damage to hood finish. 

Use soft towel to wipe off the cleaning solution, gently 

rub off any stubborn spots. Use dry soft towel to dry the hood.

After cleaning, you may use non abrasive stainless steel polish such as 3M

• 

®

 or ZEP

®

, to polish and buff out the stainless 

luster and grain. Always scrub lightly, with clean cotton cloth, and with the grain.

DO NOT allow deposits to accumulate or remain on the hood.

• 

DO NOT use ordinary steel wool or steel brushes. Small bits of steel may adhere to the surface and cause rusting.

• 

DO NOT allow salt solutions, disinfectants, bleaches, or cleaning compounds to remain in contact with stainless steel 

• 

for extended periods. Many of these compounds contain chemicals, which may be harmful. Rinse with water after ex

-

posure and wipe dry with a clean cloth.

Cleaning Aluminum Grease Filter / Stainless Steel Filterless Grill:

IMPORTANT:

 Drain oil from oil containers before oil and residue overflow!

The metal filters fitted by the factory are intended to filter out residue and grease from cooking. It need not be replaced 

• 

on a regular basis but are required to be kept clean.

Filters should be cleaned after every 30 hours of use.

• 

Remove and clean by hand or dishwasher. Spray “Formula 409

• 

®

” or equivalent degreasing detergent and leave to soak 

if heavily soiled. Dry filters and re-install before using hood.

Replacing Filters:

Should filters wear out due to age and prolonged use, please contact your local reseller for replacement filters.

• 

Note: Also replace damaged filter that has punctured or broken mesh, bent or broken frame.

• 

Replacing the light bulb:

This range hood uses halogen bulb (please refer to the actual specification of the hood purchased):

• 

   

USA/Canada:

   

 

35W Type MR16 12V / Type GU10 120V

   

Europe and other Countries:

   

 

35W Type MR16 12V / Type GU10 220V 

Make sure the range hood is unplugged or turn OFF breaker. 

• 

Make sure the lights are cool to touch, carefully align the ar

-

• 

row on the inner ring with the arrow on the outer ring where it 

says OPEN. The inner ring will loosen and the light bulb will 

be available for removal. Install a new halogen light bulb and 

reverse the steps.

Turn ON breaker and range hood to test for operation.

• 

WARNING

Hazard of Burns!

Light  bulb  become  extremely  hot  when  turned  on. 

DO  NOT  touch  bulb  until  switched  off  and  cooled. 

Touching hot bulbs could cause serious burns.

Align arrows on both rings

Page 17

Maintenance

Summary of Contents for mockingbird pro 36"

Page 1: ...nd Users Manual Wall Mount Range Hood Wall Hood NOTICE Installer Leave this guide with the homeowner Homeowner Keep this guide for future reference IMPORTANT Read and save these instructions Rev 1024u 1d Mockingbird Pro 36 ...

Page 2: ...e authorities Before servicing or cleaning unit switch power OFF at service panel and lock service panel to pre vent power from being switched ON accidentally Clean grease laden surfaces frequently To reduce the risk of fire and to disperse air properly make sure to vent air outside DO NOT vent exhaust into spaces between walls crawl spaces ceiling attics or garages Ducted fans MUST always be vent...

Page 3: ...go out immediately EVACUATE AND CALL THE FIRE DEPARTMENT or dial your local emergency service immediately DO NOT USE WATER including wet dishcloths or towels a violent steam explosion will result Use an extinguisher ONLY if You know you have a Class A B C extinguisher and you already know how to operate it The fire is small and contained in the area where it is started The fire department is being...

Page 4: ...aration 9 Installation 10 11 Installation overview 11 USE AND CARE Range hood operations 12 13 Troubleshooting 14 Use and care information 15 Specifications 15 Wiring diagram 16 MAINTENANCE Cleaning replacing filter light bulb 17 WARRANTY Coverage exceptions 18 Disclaimer contact information 19 Tools needed Page 3 Level Flat blade and Phillips screw drivers Powered screwdriver or drill Measuring t...

Page 5: ...g kit pre installed when ordered together with range hood Parts supplied Hex Key Qty 1 PCS Optional with glass canopy Glass Canopy Screw Qty 4 PCS Optional with glass canopy Qty 4 PCS For sheet rock only A Qty 4 PCS B Qty 4 to 8 PCS Vary with model C Grease Oil Cup Flexible Duct Tube Charcoal filter Optional re circulating kit pre installed when ordered together with range hood ...

Page 6: ... of the vent should be uniform Use no more than three 90 elbows Make sure there is a minimum of 24 61 cm of straight vent between the elbows if more than one elbow is used DO NOT install two elbows together The length of vent system and number of elbows should be kept to a minimum to pro vide efficient performance The vent system must have a damper If roof or wall cap has a damper DO NOT use dampe...

Page 7: ...ing elbows transitions and caps ALWAYS when possible reduce the number or transitions and turns If long duct run is required increase duct size from 6 to 7 or 8 If a reducer is used install a long reducer instead of a pancake reducer Reduc ing duct size will restrict airflow and decrease airflow thus reduce duct size as far away from opening as pos sible If turns or transitions are required Instal...

Page 8: ...resellers The standard aluminum filters are intended to capture residue from cooking the optional charcoal filters help to purify fumes exhausted from cooking and the optional air diverter redirects filtered clean air back to the house Venting Methods This range hood is factory set for venting through the roof or wall For non vented re circulating installa tions see Recirculating Non Vented Kit on...

Page 9: ...d electrical supply is required on a separate 15 amp circuit fused on both sides of the line DO NOT ground to a gas pipe Check with a qualified electrician if you are not sure that the range hood is properly grounded DO NOT have a fuse in the neutral or ground circuit IMPORTANT Save this Installation Guide for electrical inspector s use The range hood must be connected with copper wire plug only T...

Page 10: ...nd secure in the wall Put a thick protective covering over counter top cook top or range to protect from damage or dirt Remove 3 any hazardous objects around the area when installing Mark the locations of the support mounting bracket holes vent cutout if used and power supply cable cutout 4 on the ceiling Use drill and saber saw or keyhole saw to cut openings for power supply cable and vent see Ve...

Page 11: ...s if possible If stud blockings are not available it is required to build a supporting structure behind the sheet rock for best weight support Concrete wall Use designated screws not provided Wood wall Use at least 4 long wood screws not provided Fasten two Type A anchors for range hood and for mounting bracket or air diverter on the wall as shown 6 in Figure 4 Loosely fasten two Type B screws ont...

Page 12: ...tem or air diverter Make sure the main electrical supply remains disconnected then connect power plug to the electrical cord or wall plug Have one person carefully position both upper and lower chimneys on the range hood let the second person 9 slide the sides of the chimneys into the 1 16 gap Fasten both chimneys with four Type C screws Install grease cup and aluminum filters then check the opera...

Page 13: ...stem is running Power Off Delay Digital Timer Indicates the length of time left for delay off function Power Off Delay Timer Indicator Lights up when auto shutdown delay timer function is on Controls Automatic cleaning reminder This range hood is equipped with a cleaning reminder that will activate following 30 hours of use When blower motor starts to rotate cumulative running time will be shown i...

Page 14: ... will shut down Adjusting the light Press Light button once to turn on the lights and once again to turn off the lights While the lights are off press and hold Light button for over 3 seconds to dim the lights from low to high Level of brightness will be stored in system s memory CAUTION DO NOT touch the lights until switched OFFand cooled Note Light settings are independent from other settings in...

Page 15: ...ot installed correctly or opening properly A tight mesh on a side wall cap unit might also cause restriction to the air flow The lights work but the blower is not spinning at all 4 is stuck or is rattling The blower might be jammed or scraping the bot tom due to shipping damage Please contact us im mediately The hood is not venting out properly 5 Make sure the distance between the stove top and th...

Page 16: ...lowers could catch on to hair fingers and loose clothing NEVER dispose cigarette ashes ignitable substances or any foreign objects into blowers NEVER leave cooking unattended When frying oil in the pan can easily overheat and catch fire The risk of self combustion is higher when the oil has been used several times NEVER cook on open flames under the range hood Check deep fryers during use Superhea...

Page 17: ...Page 16 Wiring Diagram Six Speed with Type GU10 Bulb Six Speed with Type MR16 Bulb ...

Page 18: ...d periods Many of these compounds contain chemicals which may be harmful Rinse with water after ex posure and wipe dry with a clean cloth Cleaning Aluminum Grease Filter Stainless Steel Filterless Grill IMPORTANT Drain oil from oil containers before oil and residue overflow The metal filters fitted by the factory are intended to filter out residue and grease from cooking It need not be replaced on...

Page 19: ...nsumable parts such as light bulbs metal and charcoal filters The natural wear of finish and wear due to improper maintenance use of corrosive and abrasive cleaning products pads and oven cleaner products Chips dents or cracks due to abuse misuse freight damage or improper installation Damage of product caused by accident fire floods or act of God The manufacturer and or distributor reseller is no...

Page 20: ...ing fee of 15 will be charged for all approved return s Exchanges or returns may not be accepted if any packaging is missing Make sure to inspect the hood for damages and defects before installation Appearance flaws of the hood found after installation and not affecting hood performance is not covered under our warranty for returns or exchang es Service visits not covered under warranty will carry...

Page 21: ...Bossino Cook Till Your Hearts Content www bossino com ...

Reviews: