16
309003
6.7 Operating Procedure
I.
Read the operation section in the manual carefully before proceeding onto the initial start-up.
II. Verify the service valve is closed.
III. Pull the choke cable and start the engine. If the engine is warm or the ambient temperature is high,
pull the choke knob half-way, or keep it fully open.
IV. Allow 3-5 minutes for engine to warm-up.
V. Open service valve.
6.8 Shutdown Procedure
I.
Close service valve.
II. Allow 3-5 minutes for engine to run at low speed.
III. Turn keyswitch off.
Installation & Operation
6.9 Operating Conditions
The following conditions should exist for maximum performance of the compressor. The machine should be
as close to level as possible when operating. Operation in ambient temperatures above 100°F (38°C) may
experience high temperature shutdown.